Micromanipulation System for Isolating a Single Cryptosporidium Oocyst

In this paper, an integrated system for contact micromanipulation of Cryptosporidium oocysts is presented. The system integrates five actuators and a partially automated control system and contacts the oocyst using a drawn glass end effector with tip dimensions of 1 [Formula: see text] m. The system...