Development and validation of analytical method for the determination of radotinib in human plasma using liquid chromatography-tandem mass spectrometry

This study describes the development of an analytical method to determine radotinib levels in human plasma using high performance liquid chromatography (HPLC) coupled with triple quadrupole tandem mass spectrometry (MS/MS) for pharmacokinetic application. Plasma samples were sequentially processed b...

Descripción completa

Detalles Bibliográficos
Autores principales: Seo, Hyo-Bum, Cho, Seungil, Yoon, Young-Ran, Yim, Dong-Seok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society for Clinical Pharmacology and Therapeutics 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7033409/
https://www.ncbi.nlm.nih.gov/pubmed/32095473
http://dx.doi.org/10.12793/tcp.2017.25.4.183