Cargando…

Signal-to-Noise Ratio of Brillouin Grating Measurement with Micrometer-Resolution Optical Low Coherence Reflectometry

Signal-dependent speckle-like noise was the dominant noise in a Brillouin grating measurement with micrometer-resolution optical low coherence reflectometry (OLCR). The noise was produced by the interaction of a Stokes signal with beat noise caused by a leaked pump light via square-law detection. Th...

Descripción completa

Detalles Bibliográficos
Autores principales: Takada, Kazumasa, Satoh, Shin-ichi, Kawakami, Akiya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7038992/
https://www.ncbi.nlm.nih.gov/pubmed/32050649
http://dx.doi.org/10.3390/s20030936
_version_ 1783500745437347840
author Takada, Kazumasa
Satoh, Shin-ichi
Kawakami, Akiya
author_facet Takada, Kazumasa
Satoh, Shin-ichi
Kawakami, Akiya
author_sort Takada, Kazumasa
collection PubMed
description Signal-dependent speckle-like noise was the dominant noise in a Brillouin grating measurement with micrometer-resolution optical low coherence reflectometry (OLCR). The noise was produced by the interaction of a Stokes signal with beat noise caused by a leaked pump light via square-law detection. The resultant signal-to-noise ratio (SNR) was calculated and found to be proportional to the square root of the dynamic range (DR) defined by the ratio of the Stokes signal magnitude to the variance of the beat noise. The calculation showed that even when we achieved a DR of 20 dB on a logarithmic scale, the SNR value was only 7 on a linear scale and the detected signal tended to fluctuate over ±14% with respect to the mean level. We achieved an SNR of 24 by attenuating the pump light power entering the balanced mixer by 55 dB, and this success enabled us to measure the Brillouin spectrum distributions of mated fiber connectors and a 3-dB fused fiber coupler with a micrometer resolution as examples of OLCR diagnosis.
format Online
Article
Text
id pubmed-7038992
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-70389922020-03-09 Signal-to-Noise Ratio of Brillouin Grating Measurement with Micrometer-Resolution Optical Low Coherence Reflectometry Takada, Kazumasa Satoh, Shin-ichi Kawakami, Akiya Sensors (Basel) Article Signal-dependent speckle-like noise was the dominant noise in a Brillouin grating measurement with micrometer-resolution optical low coherence reflectometry (OLCR). The noise was produced by the interaction of a Stokes signal with beat noise caused by a leaked pump light via square-law detection. The resultant signal-to-noise ratio (SNR) was calculated and found to be proportional to the square root of the dynamic range (DR) defined by the ratio of the Stokes signal magnitude to the variance of the beat noise. The calculation showed that even when we achieved a DR of 20 dB on a logarithmic scale, the SNR value was only 7 on a linear scale and the detected signal tended to fluctuate over ±14% with respect to the mean level. We achieved an SNR of 24 by attenuating the pump light power entering the balanced mixer by 55 dB, and this success enabled us to measure the Brillouin spectrum distributions of mated fiber connectors and a 3-dB fused fiber coupler with a micrometer resolution as examples of OLCR diagnosis. MDPI 2020-02-10 /pmc/articles/PMC7038992/ /pubmed/32050649 http://dx.doi.org/10.3390/s20030936 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Takada, Kazumasa
Satoh, Shin-ichi
Kawakami, Akiya
Signal-to-Noise Ratio of Brillouin Grating Measurement with Micrometer-Resolution Optical Low Coherence Reflectometry
title Signal-to-Noise Ratio of Brillouin Grating Measurement with Micrometer-Resolution Optical Low Coherence Reflectometry
title_full Signal-to-Noise Ratio of Brillouin Grating Measurement with Micrometer-Resolution Optical Low Coherence Reflectometry
title_fullStr Signal-to-Noise Ratio of Brillouin Grating Measurement with Micrometer-Resolution Optical Low Coherence Reflectometry
title_full_unstemmed Signal-to-Noise Ratio of Brillouin Grating Measurement with Micrometer-Resolution Optical Low Coherence Reflectometry
title_short Signal-to-Noise Ratio of Brillouin Grating Measurement with Micrometer-Resolution Optical Low Coherence Reflectometry
title_sort signal-to-noise ratio of brillouin grating measurement with micrometer-resolution optical low coherence reflectometry
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7038992/
https://www.ncbi.nlm.nih.gov/pubmed/32050649
http://dx.doi.org/10.3390/s20030936
work_keys_str_mv AT takadakazumasa signaltonoiseratioofbrillouingratingmeasurementwithmicrometerresolutionopticallowcoherencereflectometry
AT satohshinichi signaltonoiseratioofbrillouingratingmeasurementwithmicrometerresolutionopticallowcoherencereflectometry
AT kawakamiakiya signaltonoiseratioofbrillouingratingmeasurementwithmicrometerresolutionopticallowcoherencereflectometry