Erosion Corrosion Behavior of Aluminum in Flowing Deionized Water at Various Temperatures
To optimize the operating temperature and flow velocity of cooling water in a high voltage direct current (HVDC) thyristor valve cooling system, the erosion corrosion characteristics of aluminum electrodes in deionized water at various temperatures were studied. With increasing water temperature, th...