Accuracy and complication rates of external ventricular drain placement with twist drill and bolt system versus standard trephine and tunnelation: a retrospective population-based study

BACKGROUND: An external ventricular drain (EVD) is typically indicated in the presence of hydrocephalus and increased intracranial pressure (ICP). Procedural challenges have prompted the development of different methods to improve accuracy, safety, and logistics. OBJECTIVES: EVD placement and compli...

Descripción completa

Detalles Bibliográficos
Autores principales: Mansoor, Nadia, Madsbu, Mattis A., Mansoor, Nina M., Trønnes, Andreas N., Fredriksli, Oddrun A., Salvesen, Øyvind, Jakola, Asgeir S., Solheim, Ole, Gulati, Sasha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Vienna 2020