Cargando…
Applying Quality by Design Principles in the Development and Preparation of a New Radiopharmaceutical: Technetium-99m-Imatinib Mesylate
[Image: see text] The clinical impact and accessibility of (99m)Tc tracers for cancer diagnosis would be greatly enhanced by the availability of a new, simple, and easy labeling process and radiopharmaceuticals. In this study, Technetium-99m-imatinib mesylate ([(99m)Tc]TcIMT) was developed and prepa...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2020
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7081423/ https://www.ncbi.nlm.nih.gov/pubmed/32201818 http://dx.doi.org/10.1021/acsomega.9b04327 |
Sumario: | [Image: see text] The clinical impact and accessibility of (99m)Tc tracers for cancer diagnosis would be greatly enhanced by the availability of a new, simple, and easy labeling process and radiopharmaceuticals. In this study, Technetium-99m-imatinib mesylate ([(99m)Tc]TcIMT) was developed and prepared as a new radiopharmaceutical for breast cancer diagnosis. The effect of critical process parameters on the product quality and stability of [(99m)Tc]TcIMT was investigated using the quality by design concept of the ICH Q8 (Pharmaceutical Development) guideline. [(99m)Tc]TcIMT was subjected to in vitro cell binding studies to determine healthy and cancer cell affinity using HaCaT and MCF-7 cells, respectively. The optimal radiolabeling procedure with 1 mg of IMT, 500 μg of stannous chloride, 0.1 mg of ascorbic acid, and (1m)Ci (99m)Tc radioactivity was obtained for [(99m)Tc]TcIMT. The pH of the reaction mixture was adjusted to 10 and allowed to react for 15 min at room temperature. The radiochemical purity of [(99m)Tc]TcIMT was found to be higher than 90% at room temperature up to 6 h. Chromatography analysis revealed >85% [(99m)Tc]TcIMT complex formation with promising stability in saline, cell medium, and serum up to 6 h. The radiolabeled complex showed a higher cell-binding ratio to MCF-7 cells (88.90% ± 3.12) than HaCaT cells (45.64 ± 4.72) when compared to (99m)Tc. Our findings show that the developed preparation method for [(99m)Tc]TcIMT falls well within the proven acceptable ranges. Applying quality by design (QbD) principles is feasible and worthwhile for the preparation of [(99m)Tc]TcIMT. In conclusion, radiochemical purity, stability, and in vitro cell binding evaluation of the [(99m)Tc]TcIMT complex indicate that the agent can be utilized for imaging of breast cancer cells. |
---|