The influence of envelope features on interunit dispersion around a naturally ventilated multi-story building

This study examines the influence of building envelope features on interunit dispersion around multi-story buildings, when the presence of an upstream interfering building is also considered. Validated CFD methods in the steady-state RANS framework are employed. In general, the reentry ratios of pol...

Descripción completa

Detalles Bibliográficos
Autores principales: Cui, Dongjin, Ai, Zhengtao, Mak, Cheuk-ming, Kwok, Kenny, Xue, Peng