A novel apparatus for non-contact measurement of heart rate variability: a system to prevent secondary exposure of medical personnel to toxic materials under biochemical hazard conditions, in monitoring sepsis or in predicting multiple organ dysfunction syndrome
BACKGROUND. The impaired balance of the low-frequency/high-frequency ratio obtained from spectral components of RR intervals can be a diagnostic test for sepsis. In addition, it is known that a reduction of heart rate variability (HRV) is useful in identifying septic patients at risk of the developm...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Published by Elsevier Masson SAS
2005
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7134716/ https://www.ncbi.nlm.nih.gov/pubmed/16275492 http://dx.doi.org/10.1016/S0753-3322(05)80030-7 |
_version_ | 1783517894184796160 |
---|---|
author | Matsui, T. Arai, I. Gotoh, S. Hattori, H. Takase, B. Kikuchi, M. Ishihara, M. |
author_facet | Matsui, T. Arai, I. Gotoh, S. Hattori, H. Takase, B. Kikuchi, M. Ishihara, M. |
author_sort | Matsui, T. |
collection | PubMed |
description | BACKGROUND. The impaired balance of the low-frequency/high-frequency ratio obtained from spectral components of RR intervals can be a diagnostic test for sepsis. In addition, it is known that a reduction of heart rate variability (HRV) is useful in identifying septic patients at risk of the development of multiple organ dysfunction syndrome (MODS). We have reported a non-contact method using a microwave radar to monitor the heart and respiratory rates of a healthy person placed inside an isolator or of experimental animals exposed to toxic materials. APPARATUS DESIGN AND TESTING. With the purpose of preventing secondary exposure of medical personnel to toxic materials under biochemical hazard conditions, we designed a novel apparatus for non-contact measurement of HRV using a 1215 MHz microwave radar, a high-pass filter, and a personal computer. The microwave radar monitors only the small reflected waves from the subject's chest wall, which are modulated by the cardiac and respiratory motion. The high-pass filter enhances the cardiac signal and attenuates the respiratory signal. In a human trial, RR intervals derived from the non-contact apparatus significantly correlated with those derived from ECG (r=0.98, P<0.0001). The non-contact apparatus showed a similar power spectrum of RR intervals to that of ECG. CONCLUSIONS. Our non-contact HRV measurement apparatus appears promising for future pre-hospital monitoring of septic patients or for predicting MODS patients, inside isolators or in the field for mass casualties under biochemical hazard circumstances. |
format | Online Article Text |
id | pubmed-7134716 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2005 |
publisher | Published by Elsevier Masson SAS |
record_format | MEDLINE/PubMed |
spelling | pubmed-71347162020-04-08 A novel apparatus for non-contact measurement of heart rate variability: a system to prevent secondary exposure of medical personnel to toxic materials under biochemical hazard conditions, in monitoring sepsis or in predicting multiple organ dysfunction syndrome Matsui, T. Arai, I. Gotoh, S. Hattori, H. Takase, B. Kikuchi, M. Ishihara, M. Biomed Pharmacother Original Paper BACKGROUND. The impaired balance of the low-frequency/high-frequency ratio obtained from spectral components of RR intervals can be a diagnostic test for sepsis. In addition, it is known that a reduction of heart rate variability (HRV) is useful in identifying septic patients at risk of the development of multiple organ dysfunction syndrome (MODS). We have reported a non-contact method using a microwave radar to monitor the heart and respiratory rates of a healthy person placed inside an isolator or of experimental animals exposed to toxic materials. APPARATUS DESIGN AND TESTING. With the purpose of preventing secondary exposure of medical personnel to toxic materials under biochemical hazard conditions, we designed a novel apparatus for non-contact measurement of HRV using a 1215 MHz microwave radar, a high-pass filter, and a personal computer. The microwave radar monitors only the small reflected waves from the subject's chest wall, which are modulated by the cardiac and respiratory motion. The high-pass filter enhances the cardiac signal and attenuates the respiratory signal. In a human trial, RR intervals derived from the non-contact apparatus significantly correlated with those derived from ECG (r=0.98, P<0.0001). The non-contact apparatus showed a similar power spectrum of RR intervals to that of ECG. CONCLUSIONS. Our non-contact HRV measurement apparatus appears promising for future pre-hospital monitoring of septic patients or for predicting MODS patients, inside isolators or in the field for mass casualties under biochemical hazard circumstances. Published by Elsevier Masson SAS 2005-10 2005-11-05 /pmc/articles/PMC7134716/ /pubmed/16275492 http://dx.doi.org/10.1016/S0753-3322(05)80030-7 Text en Copyright © 2005 Published by Elsevier Masson SAS. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Original Paper Matsui, T. Arai, I. Gotoh, S. Hattori, H. Takase, B. Kikuchi, M. Ishihara, M. A novel apparatus for non-contact measurement of heart rate variability: a system to prevent secondary exposure of medical personnel to toxic materials under biochemical hazard conditions, in monitoring sepsis or in predicting multiple organ dysfunction syndrome |
title | A novel apparatus for non-contact measurement of heart rate variability: a system to prevent secondary exposure of medical personnel to toxic materials under biochemical hazard conditions, in monitoring sepsis or in predicting multiple organ dysfunction syndrome |
title_full | A novel apparatus for non-contact measurement of heart rate variability: a system to prevent secondary exposure of medical personnel to toxic materials under biochemical hazard conditions, in monitoring sepsis or in predicting multiple organ dysfunction syndrome |
title_fullStr | A novel apparatus for non-contact measurement of heart rate variability: a system to prevent secondary exposure of medical personnel to toxic materials under biochemical hazard conditions, in monitoring sepsis or in predicting multiple organ dysfunction syndrome |
title_full_unstemmed | A novel apparatus for non-contact measurement of heart rate variability: a system to prevent secondary exposure of medical personnel to toxic materials under biochemical hazard conditions, in monitoring sepsis or in predicting multiple organ dysfunction syndrome |
title_short | A novel apparatus for non-contact measurement of heart rate variability: a system to prevent secondary exposure of medical personnel to toxic materials under biochemical hazard conditions, in monitoring sepsis or in predicting multiple organ dysfunction syndrome |
title_sort | novel apparatus for non-contact measurement of heart rate variability: a system to prevent secondary exposure of medical personnel to toxic materials under biochemical hazard conditions, in monitoring sepsis or in predicting multiple organ dysfunction syndrome |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7134716/ https://www.ncbi.nlm.nih.gov/pubmed/16275492 http://dx.doi.org/10.1016/S0753-3322(05)80030-7 |
work_keys_str_mv | AT matsuit anovelapparatusfornoncontactmeasurementofheartratevariabilityasystemtopreventsecondaryexposureofmedicalpersonneltotoxicmaterialsunderbiochemicalhazardconditionsinmonitoringsepsisorinpredictingmultipleorgandysfunctionsyndrome AT araii anovelapparatusfornoncontactmeasurementofheartratevariabilityasystemtopreventsecondaryexposureofmedicalpersonneltotoxicmaterialsunderbiochemicalhazardconditionsinmonitoringsepsisorinpredictingmultipleorgandysfunctionsyndrome AT gotohs anovelapparatusfornoncontactmeasurementofheartratevariabilityasystemtopreventsecondaryexposureofmedicalpersonneltotoxicmaterialsunderbiochemicalhazardconditionsinmonitoringsepsisorinpredictingmultipleorgandysfunctionsyndrome AT hattorih anovelapparatusfornoncontactmeasurementofheartratevariabilityasystemtopreventsecondaryexposureofmedicalpersonneltotoxicmaterialsunderbiochemicalhazardconditionsinmonitoringsepsisorinpredictingmultipleorgandysfunctionsyndrome AT takaseb anovelapparatusfornoncontactmeasurementofheartratevariabilityasystemtopreventsecondaryexposureofmedicalpersonneltotoxicmaterialsunderbiochemicalhazardconditionsinmonitoringsepsisorinpredictingmultipleorgandysfunctionsyndrome AT kikuchim anovelapparatusfornoncontactmeasurementofheartratevariabilityasystemtopreventsecondaryexposureofmedicalpersonneltotoxicmaterialsunderbiochemicalhazardconditionsinmonitoringsepsisorinpredictingmultipleorgandysfunctionsyndrome AT ishiharam anovelapparatusfornoncontactmeasurementofheartratevariabilityasystemtopreventsecondaryexposureofmedicalpersonneltotoxicmaterialsunderbiochemicalhazardconditionsinmonitoringsepsisorinpredictingmultipleorgandysfunctionsyndrome AT matsuit novelapparatusfornoncontactmeasurementofheartratevariabilityasystemtopreventsecondaryexposureofmedicalpersonneltotoxicmaterialsunderbiochemicalhazardconditionsinmonitoringsepsisorinpredictingmultipleorgandysfunctionsyndrome AT araii novelapparatusfornoncontactmeasurementofheartratevariabilityasystemtopreventsecondaryexposureofmedicalpersonneltotoxicmaterialsunderbiochemicalhazardconditionsinmonitoringsepsisorinpredictingmultipleorgandysfunctionsyndrome AT gotohs novelapparatusfornoncontactmeasurementofheartratevariabilityasystemtopreventsecondaryexposureofmedicalpersonneltotoxicmaterialsunderbiochemicalhazardconditionsinmonitoringsepsisorinpredictingmultipleorgandysfunctionsyndrome AT hattorih novelapparatusfornoncontactmeasurementofheartratevariabilityasystemtopreventsecondaryexposureofmedicalpersonneltotoxicmaterialsunderbiochemicalhazardconditionsinmonitoringsepsisorinpredictingmultipleorgandysfunctionsyndrome AT takaseb novelapparatusfornoncontactmeasurementofheartratevariabilityasystemtopreventsecondaryexposureofmedicalpersonneltotoxicmaterialsunderbiochemicalhazardconditionsinmonitoringsepsisorinpredictingmultipleorgandysfunctionsyndrome AT kikuchim novelapparatusfornoncontactmeasurementofheartratevariabilityasystemtopreventsecondaryexposureofmedicalpersonneltotoxicmaterialsunderbiochemicalhazardconditionsinmonitoringsepsisorinpredictingmultipleorgandysfunctionsyndrome AT ishiharam novelapparatusfornoncontactmeasurementofheartratevariabilityasystemtopreventsecondaryexposureofmedicalpersonneltotoxicmaterialsunderbiochemicalhazardconditionsinmonitoringsepsisorinpredictingmultipleorgandysfunctionsyndrome |