Cargando…
The Effect of Service on Microstructure and Mechanical Properties of HR3C Heat-Resistant Austenitic Stainless Steel
The physical metallurgical tests were performed on the test samples made of HR3C steel, taken from a section of a pipeline in the as-received condition and after approximately 26,000 h of service at 550 °C. In the as-received condition, the test material had austenitic microstructure with numerous l...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7142937/ https://www.ncbi.nlm.nih.gov/pubmed/32183009 http://dx.doi.org/10.3390/ma13061297 |