Cargando…
An Angle Error Compensation Method Based on Harmonic Analysis for Integrated Joint Modules
Nowadays, integrated joint modules are increasingly adopted in manipulators for their advantages of high integration, miniaturization and high repeatability positioning accuracy. The problem of generally low absolute positioning accuracy (namely angle measurement accuracy) must be solved before they...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7146274/ https://www.ncbi.nlm.nih.gov/pubmed/32204414 http://dx.doi.org/10.3390/s20061715 |
_version_ | 1783520163271802880 |
---|---|
author | Hu, Yi Zhan, Yuyi Han, Liang Hu, Penghao Ye, Bing Yu, Yue |
author_facet | Hu, Yi Zhan, Yuyi Han, Liang Hu, Penghao Ye, Bing Yu, Yue |
author_sort | Hu, Yi |
collection | PubMed |
description | Nowadays, integrated joint modules are increasingly adopted in manipulators for their advantages of high integration, miniaturization and high repeatability positioning accuracy. The problem of generally low absolute positioning accuracy (namely angle measurement accuracy) must be solved before they can be introduced into the self-driven articulated arm coordinate measuring machine which is under study in our laboratory. In this study, the sources of joint module’s angle error were analyzed and the error model based on harmonic analysis was established. Two integrated joint modules were calibrated on the self-designed calibration platform and the model parameters were deduced, respectively. The angle error was then compensated in the experiments and the results demonstrated that the angle error of the joint modules was reduced by 82.03% on average. The established angle error model can be effectively applied into the self-driven articulated arm coordinated measuring machine. |
format | Online Article Text |
id | pubmed-7146274 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-71462742020-04-15 An Angle Error Compensation Method Based on Harmonic Analysis for Integrated Joint Modules Hu, Yi Zhan, Yuyi Han, Liang Hu, Penghao Ye, Bing Yu, Yue Sensors (Basel) Article Nowadays, integrated joint modules are increasingly adopted in manipulators for their advantages of high integration, miniaturization and high repeatability positioning accuracy. The problem of generally low absolute positioning accuracy (namely angle measurement accuracy) must be solved before they can be introduced into the self-driven articulated arm coordinate measuring machine which is under study in our laboratory. In this study, the sources of joint module’s angle error were analyzed and the error model based on harmonic analysis was established. Two integrated joint modules were calibrated on the self-designed calibration platform and the model parameters were deduced, respectively. The angle error was then compensated in the experiments and the results demonstrated that the angle error of the joint modules was reduced by 82.03% on average. The established angle error model can be effectively applied into the self-driven articulated arm coordinated measuring machine. MDPI 2020-03-19 /pmc/articles/PMC7146274/ /pubmed/32204414 http://dx.doi.org/10.3390/s20061715 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Hu, Yi Zhan, Yuyi Han, Liang Hu, Penghao Ye, Bing Yu, Yue An Angle Error Compensation Method Based on Harmonic Analysis for Integrated Joint Modules |
title | An Angle Error Compensation Method Based on Harmonic Analysis for Integrated Joint Modules |
title_full | An Angle Error Compensation Method Based on Harmonic Analysis for Integrated Joint Modules |
title_fullStr | An Angle Error Compensation Method Based on Harmonic Analysis for Integrated Joint Modules |
title_full_unstemmed | An Angle Error Compensation Method Based on Harmonic Analysis for Integrated Joint Modules |
title_short | An Angle Error Compensation Method Based on Harmonic Analysis for Integrated Joint Modules |
title_sort | angle error compensation method based on harmonic analysis for integrated joint modules |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7146274/ https://www.ncbi.nlm.nih.gov/pubmed/32204414 http://dx.doi.org/10.3390/s20061715 |
work_keys_str_mv | AT huyi anangleerrorcompensationmethodbasedonharmonicanalysisforintegratedjointmodules AT zhanyuyi anangleerrorcompensationmethodbasedonharmonicanalysisforintegratedjointmodules AT hanliang anangleerrorcompensationmethodbasedonharmonicanalysisforintegratedjointmodules AT hupenghao anangleerrorcompensationmethodbasedonharmonicanalysisforintegratedjointmodules AT yebing anangleerrorcompensationmethodbasedonharmonicanalysisforintegratedjointmodules AT yuyue anangleerrorcompensationmethodbasedonharmonicanalysisforintegratedjointmodules AT huyi angleerrorcompensationmethodbasedonharmonicanalysisforintegratedjointmodules AT zhanyuyi angleerrorcompensationmethodbasedonharmonicanalysisforintegratedjointmodules AT hanliang angleerrorcompensationmethodbasedonharmonicanalysisforintegratedjointmodules AT hupenghao angleerrorcompensationmethodbasedonharmonicanalysisforintegratedjointmodules AT yebing angleerrorcompensationmethodbasedonharmonicanalysisforintegratedjointmodules AT yuyue angleerrorcompensationmethodbasedonharmonicanalysisforintegratedjointmodules |