Valgus Malalignment Due to Internally Malrotated Trochanteric Nail Placement, with Rotational Malalignment in Femoral Shaft Segmental Fracture Fixation, an Underestimated Avoidable Technical Error: A Case Report

Coronal malalignment due to malrotated trochanteric nail placement in femoral fracture fixation has never been reported. We present a case of a femoral segmental fracture fixed with a trochanteric nail, with a malrotated placement resulting in a valgus malaligned nail and femur, associated with a ro...