Difference in LET‐based biological doses between IMPT optimization techniques: Robust and PTV‐based optimizations
PURPOSE: While a large amount of experimental data suggest that the proton relative biological effectiveness (RBE) varies with both physical and biological parameters, current commercial treatment planning systems (TPS) use the constant RBE instead of variable RBE models, neglecting the dependence o...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7170293/ https://www.ncbi.nlm.nih.gov/pubmed/32150329 http://dx.doi.org/10.1002/acm2.12844 |