Cargando…

Development of an Improved Rotational Orthosis for Walking With Arm Swing and Active Ankle Control

Based on interlimb neural coupling, gait robotic systems should produce walking-like movement in both upper and lower limbs for effective walking restoration. Two orthoses were previously designed in our lab to provide passive walking with arm swing. However, an active system for walking with arm sw...

Descripción completa

Detalles Bibliográficos
Autores principales: Mu, Zaile, Zhang, Qiuju, Yang, Guo-Yuan, Xie, Le, Fang, Juan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7189750/
https://www.ncbi.nlm.nih.gov/pubmed/32390821
http://dx.doi.org/10.3389/fnbot.2020.00017
_version_ 1783527563338973184
author Mu, Zaile
Zhang, Qiuju
Yang, Guo-Yuan
Xie, Le
Fang, Juan
author_facet Mu, Zaile
Zhang, Qiuju
Yang, Guo-Yuan
Xie, Le
Fang, Juan
author_sort Mu, Zaile
collection PubMed
description Based on interlimb neural coupling, gait robotic systems should produce walking-like movement in both upper and lower limbs for effective walking restoration. Two orthoses were previously designed in our lab to provide passive walking with arm swing. However, an active system for walking with arm swing is desirable to serve as a testbed for investigation of interlimb neural coupling in response to voluntary input. Given the important function of the ankle joint during normal walking, this work aimed to develop an improved rotational orthosis for walking with arm swing, which is called ROWAS II, and especially to develop and evaluate the algorithms for active ankle control. After description of the mechanical structure and control schemes of the overall ROWAS II system, the closed-loop position control and adjustable admittance control algorithms were firstly deduced, then simulated in Matlab/Simulink and finally implemented in the ROWAS II system. Six able-bodied participants were recruited to use the ROWAS II system in passive mode, and then to estimate the active ankle mechanism. It was showed that the closed-loop position control algorithms enabled the ROWAS II system to track the target arm-leg walking movement patterns well in passive mode, with the tracking error of each joint <0.7°. The adjustable admittance control algorithms enabled the participants to voluntarily adjust the ankle movement by exerting various active force. Higher admittance gains enabled the participants to more easily adjust the movement trajectory of the ankle mechanism. The ROWAS II system is technically feasible to produce walking-like movement in the bilateral upper and lower limbs in passive mode, and the ankle mechanism has technical potential to provide various active ankle training during gait rehabilitation. This novel ROWAS II system can serve as a testbed for further investigation of interlimb neural coupling in response to voluntary ankle movement and is technically feasible to provide a new training paradigm of walking with arm swing and active ankle control.
format Online
Article
Text
id pubmed-7189750
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-71897502020-05-08 Development of an Improved Rotational Orthosis for Walking With Arm Swing and Active Ankle Control Mu, Zaile Zhang, Qiuju Yang, Guo-Yuan Xie, Le Fang, Juan Front Neurorobot Neuroscience Based on interlimb neural coupling, gait robotic systems should produce walking-like movement in both upper and lower limbs for effective walking restoration. Two orthoses were previously designed in our lab to provide passive walking with arm swing. However, an active system for walking with arm swing is desirable to serve as a testbed for investigation of interlimb neural coupling in response to voluntary input. Given the important function of the ankle joint during normal walking, this work aimed to develop an improved rotational orthosis for walking with arm swing, which is called ROWAS II, and especially to develop and evaluate the algorithms for active ankle control. After description of the mechanical structure and control schemes of the overall ROWAS II system, the closed-loop position control and adjustable admittance control algorithms were firstly deduced, then simulated in Matlab/Simulink and finally implemented in the ROWAS II system. Six able-bodied participants were recruited to use the ROWAS II system in passive mode, and then to estimate the active ankle mechanism. It was showed that the closed-loop position control algorithms enabled the ROWAS II system to track the target arm-leg walking movement patterns well in passive mode, with the tracking error of each joint <0.7°. The adjustable admittance control algorithms enabled the participants to voluntarily adjust the ankle movement by exerting various active force. Higher admittance gains enabled the participants to more easily adjust the movement trajectory of the ankle mechanism. The ROWAS II system is technically feasible to produce walking-like movement in the bilateral upper and lower limbs in passive mode, and the ankle mechanism has technical potential to provide various active ankle training during gait rehabilitation. This novel ROWAS II system can serve as a testbed for further investigation of interlimb neural coupling in response to voluntary ankle movement and is technically feasible to provide a new training paradigm of walking with arm swing and active ankle control. Frontiers Media S.A. 2020-04-22 /pmc/articles/PMC7189750/ /pubmed/32390821 http://dx.doi.org/10.3389/fnbot.2020.00017 Text en Copyright © 2020 Mu, Zhang, Yang, Xie and Fang. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Mu, Zaile
Zhang, Qiuju
Yang, Guo-Yuan
Xie, Le
Fang, Juan
Development of an Improved Rotational Orthosis for Walking With Arm Swing and Active Ankle Control
title Development of an Improved Rotational Orthosis for Walking With Arm Swing and Active Ankle Control
title_full Development of an Improved Rotational Orthosis for Walking With Arm Swing and Active Ankle Control
title_fullStr Development of an Improved Rotational Orthosis for Walking With Arm Swing and Active Ankle Control
title_full_unstemmed Development of an Improved Rotational Orthosis for Walking With Arm Swing and Active Ankle Control
title_short Development of an Improved Rotational Orthosis for Walking With Arm Swing and Active Ankle Control
title_sort development of an improved rotational orthosis for walking with arm swing and active ankle control
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7189750/
https://www.ncbi.nlm.nih.gov/pubmed/32390821
http://dx.doi.org/10.3389/fnbot.2020.00017
work_keys_str_mv AT muzaile developmentofanimprovedrotationalorthosisforwalkingwitharmswingandactiveanklecontrol
AT zhangqiuju developmentofanimprovedrotationalorthosisforwalkingwitharmswingandactiveanklecontrol
AT yangguoyuan developmentofanimprovedrotationalorthosisforwalkingwitharmswingandactiveanklecontrol
AT xiele developmentofanimprovedrotationalorthosisforwalkingwitharmswingandactiveanklecontrol
AT fangjuan developmentofanimprovedrotationalorthosisforwalkingwitharmswingandactiveanklecontrol