HPLC-MS/MS coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma
BACKGROUND: The selective occurrence of hepatotoxicity observed with use of pazopanib may be attributed to its high level of plasma protein binding and low hepatic extraction ratio. The primary objective was to investigate changes in free drug concentration amongst patients with varying albumin conc...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7191207/ https://www.ncbi.nlm.nih.gov/pubmed/32373731 http://dx.doi.org/10.1016/j.heliyon.2020.e03813 |
_version_ | 1783527818684006400 |
---|---|
author | Toh, Yi Long Pang, Yi Yun Shwe, Maung Kanesvaran, Ravindran Toh, Chee Keong Chan, Alexandre Ho, Han Kiat |
author_facet | Toh, Yi Long Pang, Yi Yun Shwe, Maung Kanesvaran, Ravindran Toh, Chee Keong Chan, Alexandre Ho, Han Kiat |
author_sort | Toh, Yi Long |
collection | PubMed |
description | BACKGROUND: The selective occurrence of hepatotoxicity observed with use of pazopanib may be attributed to its high level of plasma protein binding and low hepatic extraction ratio. The primary objective was to investigate changes in free drug concentration amongst patients with varying albumin concentrations. METHODS: A HPLC-MS/MS method using C18 column (4.6 × 150 mm, 5 μm) with ESI source in positive mode had been developed and validated for the quantitative determination of free pazaopanib concentration in human plasma. Prior to sample preparation, patient samples were subjected to 6-hour equilibrium dialysis with molecular weight cut-off set at 8000 Da. RESULTS: The calibration curves were linear over the range of 5–1000 ng/mL, with a lower limit of quantification of 5 ng/mL. The intra-day and inter-day precisions and accuracies were all within ± 15 %, at 3 different quality controls. Higher median fraction unbound of pazopanib were observed in patients (n = 17) with lower than normal albumin concentrations. CONCLUSION: With the developed assay, monitoring of plasma free concentrations may be evaluated as an indicator of pazopanib exposure in patients. |
format | Online Article Text |
id | pubmed-7191207 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-71912072020-05-05 HPLC-MS/MS coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma Toh, Yi Long Pang, Yi Yun Shwe, Maung Kanesvaran, Ravindran Toh, Chee Keong Chan, Alexandre Ho, Han Kiat Heliyon Article BACKGROUND: The selective occurrence of hepatotoxicity observed with use of pazopanib may be attributed to its high level of plasma protein binding and low hepatic extraction ratio. The primary objective was to investigate changes in free drug concentration amongst patients with varying albumin concentrations. METHODS: A HPLC-MS/MS method using C18 column (4.6 × 150 mm, 5 μm) with ESI source in positive mode had been developed and validated for the quantitative determination of free pazaopanib concentration in human plasma. Prior to sample preparation, patient samples were subjected to 6-hour equilibrium dialysis with molecular weight cut-off set at 8000 Da. RESULTS: The calibration curves were linear over the range of 5–1000 ng/mL, with a lower limit of quantification of 5 ng/mL. The intra-day and inter-day precisions and accuracies were all within ± 15 %, at 3 different quality controls. Higher median fraction unbound of pazopanib were observed in patients (n = 17) with lower than normal albumin concentrations. CONCLUSION: With the developed assay, monitoring of plasma free concentrations may be evaluated as an indicator of pazopanib exposure in patients. Elsevier 2020-04-27 /pmc/articles/PMC7191207/ /pubmed/32373731 http://dx.doi.org/10.1016/j.heliyon.2020.e03813 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article Toh, Yi Long Pang, Yi Yun Shwe, Maung Kanesvaran, Ravindran Toh, Chee Keong Chan, Alexandre Ho, Han Kiat HPLC-MS/MS coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma |
title | HPLC-MS/MS coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma |
title_full | HPLC-MS/MS coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma |
title_fullStr | HPLC-MS/MS coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma |
title_full_unstemmed | HPLC-MS/MS coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma |
title_short | HPLC-MS/MS coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma |
title_sort | hplc-ms/ms coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7191207/ https://www.ncbi.nlm.nih.gov/pubmed/32373731 http://dx.doi.org/10.1016/j.heliyon.2020.e03813 |
work_keys_str_mv | AT tohyilong hplcmsmscoupledwithequilibriumdialysismethodforquantificationoffreedrugconcentrationofpazopanibinplasma AT pangyiyun hplcmsmscoupledwithequilibriumdialysismethodforquantificationoffreedrugconcentrationofpazopanibinplasma AT shwemaung hplcmsmscoupledwithequilibriumdialysismethodforquantificationoffreedrugconcentrationofpazopanibinplasma AT kanesvaranravindran hplcmsmscoupledwithequilibriumdialysismethodforquantificationoffreedrugconcentrationofpazopanibinplasma AT tohcheekeong hplcmsmscoupledwithequilibriumdialysismethodforquantificationoffreedrugconcentrationofpazopanibinplasma AT chanalexandre hplcmsmscoupledwithequilibriumdialysismethodforquantificationoffreedrugconcentrationofpazopanibinplasma AT hohankiat hplcmsmscoupledwithequilibriumdialysismethodforquantificationoffreedrugconcentrationofpazopanibinplasma |