Cargando…

HPLC-MS/MS coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma

BACKGROUND: The selective occurrence of hepatotoxicity observed with use of pazopanib may be attributed to its high level of plasma protein binding and low hepatic extraction ratio. The primary objective was to investigate changes in free drug concentration amongst patients with varying albumin conc...

Descripción completa

Detalles Bibliográficos
Autores principales: Toh, Yi Long, Pang, Yi Yun, Shwe, Maung, Kanesvaran, Ravindran, Toh, Chee Keong, Chan, Alexandre, Ho, Han Kiat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7191207/
https://www.ncbi.nlm.nih.gov/pubmed/32373731
http://dx.doi.org/10.1016/j.heliyon.2020.e03813
_version_ 1783527818684006400
author Toh, Yi Long
Pang, Yi Yun
Shwe, Maung
Kanesvaran, Ravindran
Toh, Chee Keong
Chan, Alexandre
Ho, Han Kiat
author_facet Toh, Yi Long
Pang, Yi Yun
Shwe, Maung
Kanesvaran, Ravindran
Toh, Chee Keong
Chan, Alexandre
Ho, Han Kiat
author_sort Toh, Yi Long
collection PubMed
description BACKGROUND: The selective occurrence of hepatotoxicity observed with use of pazopanib may be attributed to its high level of plasma protein binding and low hepatic extraction ratio. The primary objective was to investigate changes in free drug concentration amongst patients with varying albumin concentrations. METHODS: A HPLC-MS/MS method using C18 column (4.6 × 150 mm, 5 μm) with ESI source in positive mode had been developed and validated for the quantitative determination of free pazaopanib concentration in human plasma. Prior to sample preparation, patient samples were subjected to 6-hour equilibrium dialysis with molecular weight cut-off set at 8000 Da. RESULTS: The calibration curves were linear over the range of 5–1000 ng/mL, with a lower limit of quantification of 5 ng/mL. The intra-day and inter-day precisions and accuracies were all within ± 15 %, at 3 different quality controls. Higher median fraction unbound of pazopanib were observed in patients (n = 17) with lower than normal albumin concentrations. CONCLUSION: With the developed assay, monitoring of plasma free concentrations may be evaluated as an indicator of pazopanib exposure in patients.
format Online
Article
Text
id pubmed-7191207
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-71912072020-05-05 HPLC-MS/MS coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma Toh, Yi Long Pang, Yi Yun Shwe, Maung Kanesvaran, Ravindran Toh, Chee Keong Chan, Alexandre Ho, Han Kiat Heliyon Article BACKGROUND: The selective occurrence of hepatotoxicity observed with use of pazopanib may be attributed to its high level of plasma protein binding and low hepatic extraction ratio. The primary objective was to investigate changes in free drug concentration amongst patients with varying albumin concentrations. METHODS: A HPLC-MS/MS method using C18 column (4.6 × 150 mm, 5 μm) with ESI source in positive mode had been developed and validated for the quantitative determination of free pazaopanib concentration in human plasma. Prior to sample preparation, patient samples were subjected to 6-hour equilibrium dialysis with molecular weight cut-off set at 8000 Da. RESULTS: The calibration curves were linear over the range of 5–1000 ng/mL, with a lower limit of quantification of 5 ng/mL. The intra-day and inter-day precisions and accuracies were all within ± 15 %, at 3 different quality controls. Higher median fraction unbound of pazopanib were observed in patients (n = 17) with lower than normal albumin concentrations. CONCLUSION: With the developed assay, monitoring of plasma free concentrations may be evaluated as an indicator of pazopanib exposure in patients. Elsevier 2020-04-27 /pmc/articles/PMC7191207/ /pubmed/32373731 http://dx.doi.org/10.1016/j.heliyon.2020.e03813 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Toh, Yi Long
Pang, Yi Yun
Shwe, Maung
Kanesvaran, Ravindran
Toh, Chee Keong
Chan, Alexandre
Ho, Han Kiat
HPLC-MS/MS coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma
title HPLC-MS/MS coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma
title_full HPLC-MS/MS coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma
title_fullStr HPLC-MS/MS coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma
title_full_unstemmed HPLC-MS/MS coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma
title_short HPLC-MS/MS coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma
title_sort hplc-ms/ms coupled with equilibrium dialysis method for quantification of free drug concentration of pazopanib in plasma
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7191207/
https://www.ncbi.nlm.nih.gov/pubmed/32373731
http://dx.doi.org/10.1016/j.heliyon.2020.e03813
work_keys_str_mv AT tohyilong hplcmsmscoupledwithequilibriumdialysismethodforquantificationoffreedrugconcentrationofpazopanibinplasma
AT pangyiyun hplcmsmscoupledwithequilibriumdialysismethodforquantificationoffreedrugconcentrationofpazopanibinplasma
AT shwemaung hplcmsmscoupledwithequilibriumdialysismethodforquantificationoffreedrugconcentrationofpazopanibinplasma
AT kanesvaranravindran hplcmsmscoupledwithequilibriumdialysismethodforquantificationoffreedrugconcentrationofpazopanibinplasma
AT tohcheekeong hplcmsmscoupledwithequilibriumdialysismethodforquantificationoffreedrugconcentrationofpazopanibinplasma
AT chanalexandre hplcmsmscoupledwithequilibriumdialysismethodforquantificationoffreedrugconcentrationofpazopanibinplasma
AT hohankiat hplcmsmscoupledwithequilibriumdialysismethodforquantificationoffreedrugconcentrationofpazopanibinplasma