Small bowel perforation caused by applicator implantation in high-dose-rate interstitial brachytherapy for recurrent pelvic tumor: a case report

High-dose-rate interstitial brachytherapy (HDR-ISBT) is widely used for the treatment of pelvic tumors. However, there are a few reports on complications of applicator implantation in HDR-ISBT. We describe a case of small bowel perforation caused by applicator implantation in an 82-year-old male pat...

Descripción completa

Detalles Bibliográficos
Autores principales: Masui, Koji, Yamazaki, Hideya, Suzuki, Gen, Shimizu, Daisuke, Takenaka, Tadashi, Yamada, Yasuhiro, Okihara, Koji, Kuriu, Yoshiaki, Yamada, Kei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7207236/
https://www.ncbi.nlm.nih.gov/pubmed/32395144
http://dx.doi.org/10.5114/jcb.2020.93875