Bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: Does additional balloon kyphoplasty retain vertebral height?

We retrospectively evaluated single-level compression fractures (T12-L3) scheduled for a short-segment POS (posterior-only stabilization) using polyaxial screws. Patients averaged 55.7 years (range, 19–65). Patients received either POS or, concomitantly, BK (balloon kyphoplasty) of the fractured ver...

Descripción completa

Detalles Bibliográficos
Autores principales: Starlinger, Julia, Lorenz, Greta, Fochtmann-Frana, Alexandra, Sarahrudi, Kambiz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7233542/
https://www.ncbi.nlm.nih.gov/pubmed/32421734
http://dx.doi.org/10.1371/journal.pone.0233240
_version_ 1783535557471633408
author Starlinger, Julia
Lorenz, Greta
Fochtmann-Frana, Alexandra
Sarahrudi, Kambiz
author_facet Starlinger, Julia
Lorenz, Greta
Fochtmann-Frana, Alexandra
Sarahrudi, Kambiz
author_sort Starlinger, Julia
collection PubMed
description We retrospectively evaluated single-level compression fractures (T12-L3) scheduled for a short-segment POS (posterior-only stabilization) using polyaxial screws. Patients averaged 55.7 years (range, 19–65). Patients received either POS or, concomitantly, BK (balloon kyphoplasty) of the fractured vertebrae as well. Primary endpoint was the radiological outcome at the last radiographic follow-up prior to implant removal. POS together with BK of the fractured vertebrae resulted in a significant improvement of the local kyphosis angle and vertebral body compression rates immediately post-OP. During the further course of FU, a considerable loss of correction was observed post-OP in both groups. (Local KA: pre-OP/ post-OP/ FU: 12.6±4.8/ 3.35±4.8/ 11.6±6.0; anterior vertebral body compression%: pre-OP/post-OP/ FU: 71.94±12.3/ 94.78±19.95/ 78.17±14.74). VAS was significantly improved from 7.2±1.3 pre-OP to 2.7±1.3 (P<0.001) at FU. We found a significant restoration of the vertebral body height by BK. Nevertheless, follow-up revealed a noticeable loss of reduction. Given the fact that BK used together with polyaxial screws did not maintain intra-operative reduction, our data do not support this additional maneuver when used together with bi-segmental polyaxial pedicle screw fixation.
format Online
Article
Text
id pubmed-7233542
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-72335422020-06-02 Bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: Does additional balloon kyphoplasty retain vertebral height? Starlinger, Julia Lorenz, Greta Fochtmann-Frana, Alexandra Sarahrudi, Kambiz PLoS One Research Article We retrospectively evaluated single-level compression fractures (T12-L3) scheduled for a short-segment POS (posterior-only stabilization) using polyaxial screws. Patients averaged 55.7 years (range, 19–65). Patients received either POS or, concomitantly, BK (balloon kyphoplasty) of the fractured vertebrae as well. Primary endpoint was the radiological outcome at the last radiographic follow-up prior to implant removal. POS together with BK of the fractured vertebrae resulted in a significant improvement of the local kyphosis angle and vertebral body compression rates immediately post-OP. During the further course of FU, a considerable loss of correction was observed post-OP in both groups. (Local KA: pre-OP/ post-OP/ FU: 12.6±4.8/ 3.35±4.8/ 11.6±6.0; anterior vertebral body compression%: pre-OP/post-OP/ FU: 71.94±12.3/ 94.78±19.95/ 78.17±14.74). VAS was significantly improved from 7.2±1.3 pre-OP to 2.7±1.3 (P<0.001) at FU. We found a significant restoration of the vertebral body height by BK. Nevertheless, follow-up revealed a noticeable loss of reduction. Given the fact that BK used together with polyaxial screws did not maintain intra-operative reduction, our data do not support this additional maneuver when used together with bi-segmental polyaxial pedicle screw fixation. Public Library of Science 2020-05-18 /pmc/articles/PMC7233542/ /pubmed/32421734 http://dx.doi.org/10.1371/journal.pone.0233240 Text en © 2020 Starlinger et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Starlinger, Julia
Lorenz, Greta
Fochtmann-Frana, Alexandra
Sarahrudi, Kambiz
Bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: Does additional balloon kyphoplasty retain vertebral height?
title Bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: Does additional balloon kyphoplasty retain vertebral height?
title_full Bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: Does additional balloon kyphoplasty retain vertebral height?
title_fullStr Bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: Does additional balloon kyphoplasty retain vertebral height?
title_full_unstemmed Bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: Does additional balloon kyphoplasty retain vertebral height?
title_short Bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: Does additional balloon kyphoplasty retain vertebral height?
title_sort bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: does additional balloon kyphoplasty retain vertebral height?
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7233542/
https://www.ncbi.nlm.nih.gov/pubmed/32421734
http://dx.doi.org/10.1371/journal.pone.0233240
work_keys_str_mv AT starlingerjulia bisegmentalposteriorstabilisationofthoracolumbarfractureswithpolyaxialpediclescrewsdoesadditionalballoonkyphoplastyretainvertebralheight
AT lorenzgreta bisegmentalposteriorstabilisationofthoracolumbarfractureswithpolyaxialpediclescrewsdoesadditionalballoonkyphoplastyretainvertebralheight
AT fochtmannfranaalexandra bisegmentalposteriorstabilisationofthoracolumbarfractureswithpolyaxialpediclescrewsdoesadditionalballoonkyphoplastyretainvertebralheight
AT sarahrudikambiz bisegmentalposteriorstabilisationofthoracolumbarfractureswithpolyaxialpediclescrewsdoesadditionalballoonkyphoplastyretainvertebralheight