Bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: Does additional balloon kyphoplasty retain vertebral height?
We retrospectively evaluated single-level compression fractures (T12-L3) scheduled for a short-segment POS (posterior-only stabilization) using polyaxial screws. Patients averaged 55.7 years (range, 19–65). Patients received either POS or, concomitantly, BK (balloon kyphoplasty) of the fractured ver...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7233542/ https://www.ncbi.nlm.nih.gov/pubmed/32421734 http://dx.doi.org/10.1371/journal.pone.0233240 |
_version_ | 1783535557471633408 |
---|---|
author | Starlinger, Julia Lorenz, Greta Fochtmann-Frana, Alexandra Sarahrudi, Kambiz |
author_facet | Starlinger, Julia Lorenz, Greta Fochtmann-Frana, Alexandra Sarahrudi, Kambiz |
author_sort | Starlinger, Julia |
collection | PubMed |
description | We retrospectively evaluated single-level compression fractures (T12-L3) scheduled for a short-segment POS (posterior-only stabilization) using polyaxial screws. Patients averaged 55.7 years (range, 19–65). Patients received either POS or, concomitantly, BK (balloon kyphoplasty) of the fractured vertebrae as well. Primary endpoint was the radiological outcome at the last radiographic follow-up prior to implant removal. POS together with BK of the fractured vertebrae resulted in a significant improvement of the local kyphosis angle and vertebral body compression rates immediately post-OP. During the further course of FU, a considerable loss of correction was observed post-OP in both groups. (Local KA: pre-OP/ post-OP/ FU: 12.6±4.8/ 3.35±4.8/ 11.6±6.0; anterior vertebral body compression%: pre-OP/post-OP/ FU: 71.94±12.3/ 94.78±19.95/ 78.17±14.74). VAS was significantly improved from 7.2±1.3 pre-OP to 2.7±1.3 (P<0.001) at FU. We found a significant restoration of the vertebral body height by BK. Nevertheless, follow-up revealed a noticeable loss of reduction. Given the fact that BK used together with polyaxial screws did not maintain intra-operative reduction, our data do not support this additional maneuver when used together with bi-segmental polyaxial pedicle screw fixation. |
format | Online Article Text |
id | pubmed-7233542 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-72335422020-06-02 Bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: Does additional balloon kyphoplasty retain vertebral height? Starlinger, Julia Lorenz, Greta Fochtmann-Frana, Alexandra Sarahrudi, Kambiz PLoS One Research Article We retrospectively evaluated single-level compression fractures (T12-L3) scheduled for a short-segment POS (posterior-only stabilization) using polyaxial screws. Patients averaged 55.7 years (range, 19–65). Patients received either POS or, concomitantly, BK (balloon kyphoplasty) of the fractured vertebrae as well. Primary endpoint was the radiological outcome at the last radiographic follow-up prior to implant removal. POS together with BK of the fractured vertebrae resulted in a significant improvement of the local kyphosis angle and vertebral body compression rates immediately post-OP. During the further course of FU, a considerable loss of correction was observed post-OP in both groups. (Local KA: pre-OP/ post-OP/ FU: 12.6±4.8/ 3.35±4.8/ 11.6±6.0; anterior vertebral body compression%: pre-OP/post-OP/ FU: 71.94±12.3/ 94.78±19.95/ 78.17±14.74). VAS was significantly improved from 7.2±1.3 pre-OP to 2.7±1.3 (P<0.001) at FU. We found a significant restoration of the vertebral body height by BK. Nevertheless, follow-up revealed a noticeable loss of reduction. Given the fact that BK used together with polyaxial screws did not maintain intra-operative reduction, our data do not support this additional maneuver when used together with bi-segmental polyaxial pedicle screw fixation. Public Library of Science 2020-05-18 /pmc/articles/PMC7233542/ /pubmed/32421734 http://dx.doi.org/10.1371/journal.pone.0233240 Text en © 2020 Starlinger et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Starlinger, Julia Lorenz, Greta Fochtmann-Frana, Alexandra Sarahrudi, Kambiz Bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: Does additional balloon kyphoplasty retain vertebral height? |
title | Bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: Does additional balloon kyphoplasty retain vertebral height? |
title_full | Bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: Does additional balloon kyphoplasty retain vertebral height? |
title_fullStr | Bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: Does additional balloon kyphoplasty retain vertebral height? |
title_full_unstemmed | Bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: Does additional balloon kyphoplasty retain vertebral height? |
title_short | Bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: Does additional balloon kyphoplasty retain vertebral height? |
title_sort | bisegmental posterior stabilisation of thoracolumbar fractures with polyaxial pedicle screws: does additional balloon kyphoplasty retain vertebral height? |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7233542/ https://www.ncbi.nlm.nih.gov/pubmed/32421734 http://dx.doi.org/10.1371/journal.pone.0233240 |
work_keys_str_mv | AT starlingerjulia bisegmentalposteriorstabilisationofthoracolumbarfractureswithpolyaxialpediclescrewsdoesadditionalballoonkyphoplastyretainvertebralheight AT lorenzgreta bisegmentalposteriorstabilisationofthoracolumbarfractureswithpolyaxialpediclescrewsdoesadditionalballoonkyphoplastyretainvertebralheight AT fochtmannfranaalexandra bisegmentalposteriorstabilisationofthoracolumbarfractureswithpolyaxialpediclescrewsdoesadditionalballoonkyphoplastyretainvertebralheight AT sarahrudikambiz bisegmentalposteriorstabilisationofthoracolumbarfractureswithpolyaxialpediclescrewsdoesadditionalballoonkyphoplastyretainvertebralheight |