Cargando…

RIFTA: A Robust Iterative Fourier Transform-based dwell time Algorithm for ultra-precision ion beam figuring of synchrotron mirrors

With the rapid evolution of synchrotron X-ray sources, the demand for high-precision X-ray mirrors has greatly increased. Single nanometer profile error is required to keep imaging capability at the diffraction limit. Ion Beam Figuring (IBF), as a highly deterministic surfacing technique, has been u...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Tianyi, Huang, Lei, Kang, Hyukmo, Choi, Heejoo, Kim, Dae Wook, Tayabaly, Kashmira, Idir, Mourad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7235036/
https://www.ncbi.nlm.nih.gov/pubmed/32424222
http://dx.doi.org/10.1038/s41598-020-64923-3
_version_ 1783535889518952448
author Wang, Tianyi
Huang, Lei
Kang, Hyukmo
Choi, Heejoo
Kim, Dae Wook
Tayabaly, Kashmira
Idir, Mourad
author_facet Wang, Tianyi
Huang, Lei
Kang, Hyukmo
Choi, Heejoo
Kim, Dae Wook
Tayabaly, Kashmira
Idir, Mourad
author_sort Wang, Tianyi
collection PubMed
description With the rapid evolution of synchrotron X-ray sources, the demand for high-precision X-ray mirrors has greatly increased. Single nanometer profile error is required to keep imaging capability at the diffraction limit. Ion Beam Figuring (IBF), as a highly deterministic surfacing technique, has been used for ultra-precision finishing of mirrors. One crucial step that guides the IBF process is dwell time calculation. A valid dwell time solution should be non-negative and duplicate the shape of the desired removal map. Another important aspect is to minimize the total dwell time. In this study, we propose a Robust Iterative Fourier Transform-based dwell time Algorithm (RIFTA) that automatically fulfills these requirements. First, the thresholded inverse filtering in Fourier transform-based deconvolution is stabilized and automated by optimizing the threshold value using the Nelder-Mead simplex algorithm. Second, a novel two-level iterative scheme is proposed to guarantee the minimized total dwell time with its non-negativity at each dwell point. Third, a bicubic resampling is employed to flexibly adapt the calculated dwell time map to any IBF process intervals. The performance of RIFTA is first studied with simulation, followed by a comparison with the other state-of-the-art dwell time algorithms. We then demonstrate with an experiment that, using the dwell time calculated by the RIFTA, the total dwell time is shortened by a factor of two and the RMS in a 5 × 50 mm clear aperture was reduced from 3.4 nm to 1.1 nm after one IBF run, which proves the effectiveness and the efficiency of the proposed algorithm.
format Online
Article
Text
id pubmed-7235036
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-72350362020-05-26 RIFTA: A Robust Iterative Fourier Transform-based dwell time Algorithm for ultra-precision ion beam figuring of synchrotron mirrors Wang, Tianyi Huang, Lei Kang, Hyukmo Choi, Heejoo Kim, Dae Wook Tayabaly, Kashmira Idir, Mourad Sci Rep Article With the rapid evolution of synchrotron X-ray sources, the demand for high-precision X-ray mirrors has greatly increased. Single nanometer profile error is required to keep imaging capability at the diffraction limit. Ion Beam Figuring (IBF), as a highly deterministic surfacing technique, has been used for ultra-precision finishing of mirrors. One crucial step that guides the IBF process is dwell time calculation. A valid dwell time solution should be non-negative and duplicate the shape of the desired removal map. Another important aspect is to minimize the total dwell time. In this study, we propose a Robust Iterative Fourier Transform-based dwell time Algorithm (RIFTA) that automatically fulfills these requirements. First, the thresholded inverse filtering in Fourier transform-based deconvolution is stabilized and automated by optimizing the threshold value using the Nelder-Mead simplex algorithm. Second, a novel two-level iterative scheme is proposed to guarantee the minimized total dwell time with its non-negativity at each dwell point. Third, a bicubic resampling is employed to flexibly adapt the calculated dwell time map to any IBF process intervals. The performance of RIFTA is first studied with simulation, followed by a comparison with the other state-of-the-art dwell time algorithms. We then demonstrate with an experiment that, using the dwell time calculated by the RIFTA, the total dwell time is shortened by a factor of two and the RMS in a 5 × 50 mm clear aperture was reduced from 3.4 nm to 1.1 nm after one IBF run, which proves the effectiveness and the efficiency of the proposed algorithm. Nature Publishing Group UK 2020-05-18 /pmc/articles/PMC7235036/ /pubmed/32424222 http://dx.doi.org/10.1038/s41598-020-64923-3 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Wang, Tianyi
Huang, Lei
Kang, Hyukmo
Choi, Heejoo
Kim, Dae Wook
Tayabaly, Kashmira
Idir, Mourad
RIFTA: A Robust Iterative Fourier Transform-based dwell time Algorithm for ultra-precision ion beam figuring of synchrotron mirrors
title RIFTA: A Robust Iterative Fourier Transform-based dwell time Algorithm for ultra-precision ion beam figuring of synchrotron mirrors
title_full RIFTA: A Robust Iterative Fourier Transform-based dwell time Algorithm for ultra-precision ion beam figuring of synchrotron mirrors
title_fullStr RIFTA: A Robust Iterative Fourier Transform-based dwell time Algorithm for ultra-precision ion beam figuring of synchrotron mirrors
title_full_unstemmed RIFTA: A Robust Iterative Fourier Transform-based dwell time Algorithm for ultra-precision ion beam figuring of synchrotron mirrors
title_short RIFTA: A Robust Iterative Fourier Transform-based dwell time Algorithm for ultra-precision ion beam figuring of synchrotron mirrors
title_sort rifta: a robust iterative fourier transform-based dwell time algorithm for ultra-precision ion beam figuring of synchrotron mirrors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7235036/
https://www.ncbi.nlm.nih.gov/pubmed/32424222
http://dx.doi.org/10.1038/s41598-020-64923-3
work_keys_str_mv AT wangtianyi riftaarobustiterativefouriertransformbaseddwelltimealgorithmforultraprecisionionbeamfiguringofsynchrotronmirrors
AT huanglei riftaarobustiterativefouriertransformbaseddwelltimealgorithmforultraprecisionionbeamfiguringofsynchrotronmirrors
AT kanghyukmo riftaarobustiterativefouriertransformbaseddwelltimealgorithmforultraprecisionionbeamfiguringofsynchrotronmirrors
AT choiheejoo riftaarobustiterativefouriertransformbaseddwelltimealgorithmforultraprecisionionbeamfiguringofsynchrotronmirrors
AT kimdaewook riftaarobustiterativefouriertransformbaseddwelltimealgorithmforultraprecisionionbeamfiguringofsynchrotronmirrors
AT tayabalykashmira riftaarobustiterativefouriertransformbaseddwelltimealgorithmforultraprecisionionbeamfiguringofsynchrotronmirrors
AT idirmourad riftaarobustiterativefouriertransformbaseddwelltimealgorithmforultraprecisionionbeamfiguringofsynchrotronmirrors