Cargando…

Development of UHPLC-MS/MS Method for Indirubin-3′-Oxime Derivative as a Novel FLT3 Inhibitor and Pharmacokinetic Study in Rats

This study aimed to develop and validate a sensitive liquid chromatography-coupled tandem mass spectrometry method for the quantification of LDD-2614, an indirubin derivative and novel FLT3 inhibitor, in rat plasma. In addition, the developed analytical method was applied to observe the pharmacokine...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Na Yoon, Kim, Yong-Chul, Kim, Yoon Gyoon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7248905/
https://www.ncbi.nlm.nih.gov/pubmed/32349415
http://dx.doi.org/10.3390/molecules25092039
_version_ 1783538479146205184
author Kim, Na Yoon
Kim, Yong-Chul
Kim, Yoon Gyoon
author_facet Kim, Na Yoon
Kim, Yong-Chul
Kim, Yoon Gyoon
author_sort Kim, Na Yoon
collection PubMed
description This study aimed to develop and validate a sensitive liquid chromatography-coupled tandem mass spectrometry method for the quantification of LDD-2614, an indirubin derivative and novel FLT3 inhibitor, in rat plasma. In addition, the developed analytical method was applied to observe the pharmacokinetic properties of LDD-2614. Chromatographic separation was achieved on a Luna omega C(18) column using a mixture of water and acetonitrile, both containing 0.1% formic acid. Quantitation was performed using positive electrospray ionization in a multiple reaction monitoring (MRM) mode. The MRM transitions were optimized as m/z 426.2→113.1 for LDD-2614 and m/z 390.2→113.1 for LDD-2633 (internal standard), and the lower limit of quantification (LLOQ) for LDD-2614 was determined as 0.1 ng/mL. Including the LLOQ, the nine-point calibration curve was linear with a correlation coefficient greater than 0.9991. Inter- and intraday accuracies (RE) ranged from −3.19% to 8.72%, and the precision was within 9.02%. All validation results (accuracy, precision, matrix effect, recovery, stability, and dilution integrity) met the acceptance criteria of the U.S. Food and Drug Administration and the Korea Ministry of Food and Drug Safety guidelines. The proposed method was validated and demonstrated to be suitable for the quantification of LDD-2614 for pharmacokinetics studies.
format Online
Article
Text
id pubmed-7248905
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-72489052020-06-10 Development of UHPLC-MS/MS Method for Indirubin-3′-Oxime Derivative as a Novel FLT3 Inhibitor and Pharmacokinetic Study in Rats Kim, Na Yoon Kim, Yong-Chul Kim, Yoon Gyoon Molecules Article This study aimed to develop and validate a sensitive liquid chromatography-coupled tandem mass spectrometry method for the quantification of LDD-2614, an indirubin derivative and novel FLT3 inhibitor, in rat plasma. In addition, the developed analytical method was applied to observe the pharmacokinetic properties of LDD-2614. Chromatographic separation was achieved on a Luna omega C(18) column using a mixture of water and acetonitrile, both containing 0.1% formic acid. Quantitation was performed using positive electrospray ionization in a multiple reaction monitoring (MRM) mode. The MRM transitions were optimized as m/z 426.2→113.1 for LDD-2614 and m/z 390.2→113.1 for LDD-2633 (internal standard), and the lower limit of quantification (LLOQ) for LDD-2614 was determined as 0.1 ng/mL. Including the LLOQ, the nine-point calibration curve was linear with a correlation coefficient greater than 0.9991. Inter- and intraday accuracies (RE) ranged from −3.19% to 8.72%, and the precision was within 9.02%. All validation results (accuracy, precision, matrix effect, recovery, stability, and dilution integrity) met the acceptance criteria of the U.S. Food and Drug Administration and the Korea Ministry of Food and Drug Safety guidelines. The proposed method was validated and demonstrated to be suitable for the quantification of LDD-2614 for pharmacokinetics studies. MDPI 2020-04-27 /pmc/articles/PMC7248905/ /pubmed/32349415 http://dx.doi.org/10.3390/molecules25092039 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kim, Na Yoon
Kim, Yong-Chul
Kim, Yoon Gyoon
Development of UHPLC-MS/MS Method for Indirubin-3′-Oxime Derivative as a Novel FLT3 Inhibitor and Pharmacokinetic Study in Rats
title Development of UHPLC-MS/MS Method for Indirubin-3′-Oxime Derivative as a Novel FLT3 Inhibitor and Pharmacokinetic Study in Rats
title_full Development of UHPLC-MS/MS Method for Indirubin-3′-Oxime Derivative as a Novel FLT3 Inhibitor and Pharmacokinetic Study in Rats
title_fullStr Development of UHPLC-MS/MS Method for Indirubin-3′-Oxime Derivative as a Novel FLT3 Inhibitor and Pharmacokinetic Study in Rats
title_full_unstemmed Development of UHPLC-MS/MS Method for Indirubin-3′-Oxime Derivative as a Novel FLT3 Inhibitor and Pharmacokinetic Study in Rats
title_short Development of UHPLC-MS/MS Method for Indirubin-3′-Oxime Derivative as a Novel FLT3 Inhibitor and Pharmacokinetic Study in Rats
title_sort development of uhplc-ms/ms method for indirubin-3′-oxime derivative as a novel flt3 inhibitor and pharmacokinetic study in rats
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7248905/
https://www.ncbi.nlm.nih.gov/pubmed/32349415
http://dx.doi.org/10.3390/molecules25092039
work_keys_str_mv AT kimnayoon developmentofuhplcmsmsmethodforindirubin3oximederivativeasanovelflt3inhibitorandpharmacokineticstudyinrats
AT kimyongchul developmentofuhplcmsmsmethodforindirubin3oximederivativeasanovelflt3inhibitorandpharmacokineticstudyinrats
AT kimyoongyoon developmentofuhplcmsmsmethodforindirubin3oximederivativeasanovelflt3inhibitorandpharmacokineticstudyinrats