Cargando…

Comparison of Two Tube-Modification Techniques in Baerveldt Glaucoma Implantation in Refractory Glaucoma

IMPORTANCE: To compare treatment outcomes among a stent group, ligature group and combined group in eyes with refractory glaucoma. BACKGROUND: Various techniques have been used intra-operatively to restrict the aqueous flow in Baerveldt glaucoma implantation. DESIGN: Retrospective chart review. PART...

Descripción completa

Detalles Bibliográficos
Autores principales: Petpiroon, Purit, Vijittrakarnrung, Thanyathorn, Supakontanasan, Wasu, Tantraworasin, Apichat, Suwan, Yanin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7311164/
https://www.ncbi.nlm.nih.gov/pubmed/32606584
http://dx.doi.org/10.2147/OPTH.S246905