Cargando…
Towards improving the accuracy of aortic transvalvular pressure gradients: rethinking Bernoulli
The transvalvular pressure gradient (TPG) is commonly estimated using the Bernoulli equation. However, the method is known to be inaccurate. Therefore, an adjusted Bernoulli model for accurate TPG assessment was developed and evaluated. Numerical simulations were used to calculate TPG(CFD) in patien...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7340661/ https://www.ncbi.nlm.nih.gov/pubmed/32451697 http://dx.doi.org/10.1007/s11517-020-02186-w |