Cargando…

FT-NIRS Coupled with PLS Regression as a Complement to HPLC Routine Analysis of Caffeine in Tea Samples

Daily consumption of caffeine in coffee, tea, chocolate, cocoa, and soft drinks has gained wide and plentiful public and scientific attention over the past few decades. The concentration of caffeine in vivo is a crucial indicator of some disorders—for example, kidney malfunction, heart disease, incr...

Descripción completa

Detalles Bibliográficos
Autores principales: Ur Rehman, Najeeb, Al-Harrasi, Ahmed, Boqué, Ricard, Mabood, Fazal, Al-Broumi, Muhammed, Hussain, Javid, Alameri, Saif
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7353657/
https://www.ncbi.nlm.nih.gov/pubmed/32599832
http://dx.doi.org/10.3390/foods9060827
_version_ 1783557927709179904
author Ur Rehman, Najeeb
Al-Harrasi, Ahmed
Boqué, Ricard
Mabood, Fazal
Al-Broumi, Muhammed
Hussain, Javid
Alameri, Saif
author_facet Ur Rehman, Najeeb
Al-Harrasi, Ahmed
Boqué, Ricard
Mabood, Fazal
Al-Broumi, Muhammed
Hussain, Javid
Alameri, Saif
author_sort Ur Rehman, Najeeb
collection PubMed
description Daily consumption of caffeine in coffee, tea, chocolate, cocoa, and soft drinks has gained wide and plentiful public and scientific attention over the past few decades. The concentration of caffeine in vivo is a crucial indicator of some disorders—for example, kidney malfunction, heart disease, increase of blood pressure and alertness—and can cause some severe diseases including type 2 diabetes mellitus (DM), stroke risk, liver disease, and some cancers. In the present study, near-infrared spectroscopy (NIRS) coupled with partial least-squares regression (PLSR) was proposed as an alternative method for the quantification of caffeine in 25 commercially available tea samples consumed in Oman. This method is a fast, complementary technique to wet chemistry procedures as well as to high-performance liquid chromatography (HPLC) methods for the quantitative analysis of caffeine in tea samples because it is reagent-less and needs little or no pre-treatment of samples. In the current study, the partial least-squares (PLS) algorithm was built by using the near-infrared NIR spectra of caffeine standards prepared in tea samples scanned by a Frontier NIR spectrophotometer (L1280034) by PerkinElmer. Spectra were collected in the absorption mode in the wavenumber range of 10,000–4000 cm(−1), using a 0.2 mm path length and CaF(2) sealed cells with a resolution of 2 cm(−1). The NIR results for the contents of caffeine in tea samples were also compared with results obtained by HPLC analysis. Both techniques provided good results for predicting the caffeine contents in commercially available tea samples. The results of the proposed study show that the suggested FT-NIRS coupled with PLS regression algorithun has a high potential to be routinely used for the quick and reproducible analysis of caffeine contents in tea samples. For the NIR method, the limit of quantification (LOQ) was estimated as 10 times the error of calibration (root mean square error of calibration (RMSECV)) of the model; thus, RMSEC was calculated as 0.03 ppm and the LOQ as 0.3 ppm.
format Online
Article
Text
id pubmed-7353657
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73536572020-07-21 FT-NIRS Coupled with PLS Regression as a Complement to HPLC Routine Analysis of Caffeine in Tea Samples Ur Rehman, Najeeb Al-Harrasi, Ahmed Boqué, Ricard Mabood, Fazal Al-Broumi, Muhammed Hussain, Javid Alameri, Saif Foods Communication Daily consumption of caffeine in coffee, tea, chocolate, cocoa, and soft drinks has gained wide and plentiful public and scientific attention over the past few decades. The concentration of caffeine in vivo is a crucial indicator of some disorders—for example, kidney malfunction, heart disease, increase of blood pressure and alertness—and can cause some severe diseases including type 2 diabetes mellitus (DM), stroke risk, liver disease, and some cancers. In the present study, near-infrared spectroscopy (NIRS) coupled with partial least-squares regression (PLSR) was proposed as an alternative method for the quantification of caffeine in 25 commercially available tea samples consumed in Oman. This method is a fast, complementary technique to wet chemistry procedures as well as to high-performance liquid chromatography (HPLC) methods for the quantitative analysis of caffeine in tea samples because it is reagent-less and needs little or no pre-treatment of samples. In the current study, the partial least-squares (PLS) algorithm was built by using the near-infrared NIR spectra of caffeine standards prepared in tea samples scanned by a Frontier NIR spectrophotometer (L1280034) by PerkinElmer. Spectra were collected in the absorption mode in the wavenumber range of 10,000–4000 cm(−1), using a 0.2 mm path length and CaF(2) sealed cells with a resolution of 2 cm(−1). The NIR results for the contents of caffeine in tea samples were also compared with results obtained by HPLC analysis. Both techniques provided good results for predicting the caffeine contents in commercially available tea samples. The results of the proposed study show that the suggested FT-NIRS coupled with PLS regression algorithun has a high potential to be routinely used for the quick and reproducible analysis of caffeine contents in tea samples. For the NIR method, the limit of quantification (LOQ) was estimated as 10 times the error of calibration (root mean square error of calibration (RMSECV)) of the model; thus, RMSEC was calculated as 0.03 ppm and the LOQ as 0.3 ppm. MDPI 2020-06-24 /pmc/articles/PMC7353657/ /pubmed/32599832 http://dx.doi.org/10.3390/foods9060827 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Ur Rehman, Najeeb
Al-Harrasi, Ahmed
Boqué, Ricard
Mabood, Fazal
Al-Broumi, Muhammed
Hussain, Javid
Alameri, Saif
FT-NIRS Coupled with PLS Regression as a Complement to HPLC Routine Analysis of Caffeine in Tea Samples
title FT-NIRS Coupled with PLS Regression as a Complement to HPLC Routine Analysis of Caffeine in Tea Samples
title_full FT-NIRS Coupled with PLS Regression as a Complement to HPLC Routine Analysis of Caffeine in Tea Samples
title_fullStr FT-NIRS Coupled with PLS Regression as a Complement to HPLC Routine Analysis of Caffeine in Tea Samples
title_full_unstemmed FT-NIRS Coupled with PLS Regression as a Complement to HPLC Routine Analysis of Caffeine in Tea Samples
title_short FT-NIRS Coupled with PLS Regression as a Complement to HPLC Routine Analysis of Caffeine in Tea Samples
title_sort ft-nirs coupled with pls regression as a complement to hplc routine analysis of caffeine in tea samples
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7353657/
https://www.ncbi.nlm.nih.gov/pubmed/32599832
http://dx.doi.org/10.3390/foods9060827
work_keys_str_mv AT urrehmannajeeb ftnirscoupledwithplsregressionasacomplementtohplcroutineanalysisofcaffeineinteasamples
AT alharrasiahmed ftnirscoupledwithplsregressionasacomplementtohplcroutineanalysisofcaffeineinteasamples
AT boquericard ftnirscoupledwithplsregressionasacomplementtohplcroutineanalysisofcaffeineinteasamples
AT maboodfazal ftnirscoupledwithplsregressionasacomplementtohplcroutineanalysisofcaffeineinteasamples
AT albroumimuhammed ftnirscoupledwithplsregressionasacomplementtohplcroutineanalysisofcaffeineinteasamples
AT hussainjavid ftnirscoupledwithplsregressionasacomplementtohplcroutineanalysisofcaffeineinteasamples
AT alamerisaif ftnirscoupledwithplsregressionasacomplementtohplcroutineanalysisofcaffeineinteasamples