Cargando…

Risk factors for iliopsoas impingement after total hip arthroplasty using a collared femoral prosthesis

BACKGROUND: The relationship between collar design of a femoral component and iliopsoas impingement (IPI) after total hip arthroplasty (THA) is still underrecognized. The purpose of our study was to determine the possible risk factors for IPI related to the femoral component, when using a collared f...

Descripción completa

Detalles Bibliográficos
Autores principales: Qiu, Jiandi, Ke, Xiurong, Chen, Shanxi, Zhao, Liben, Wu, Fanghui, Yang, Guojing, Zhang, Lei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7364523/
https://www.ncbi.nlm.nih.gov/pubmed/32677980
http://dx.doi.org/10.1186/s13018-020-01787-3