Cold flush after dynamic liver preservation protects against ischemic changes upon reperfusion – an experimental study

Ex vivo machine perfusion of the liver after cold storage has found to be most effective if combined with controlled oxygenated rewarming up to (sub)‐normothermia. On disconnection of the warm graft from the machine, most surgeons usually perform a cold flush of the organ as protection against the s...

Descripción completa

Detalles Bibliográficos
Autores principales: von Horn, Charlotte, Hannaert, Patrick, Hauet, Thierry, Leuvenink, Henri, Paul, Andreas, Minor, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7380013/
https://www.ncbi.nlm.nih.gov/pubmed/30251360
http://dx.doi.org/10.1111/tri.13354