Cargando…
Comparison of Glidescope(®) Go(™), King Vision(™), Dahlhausen VL, I‑View(™) and Macintosh laryngoscope use during difficult airway management simulation by experienced and inexperienced emergency medical staff: A randomized crossover manikin study
BACKGROUND: In pre-hospital emergency care, video laryngoscopes (VLs) with disposable blades are preferably used due to hygienic reasons. However, there is limited existing data on the use of VLs with disposable blades by emergency medical staff. Therefore, the aim of this study was to compare the e...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7392330/ https://www.ncbi.nlm.nih.gov/pubmed/32730283 http://dx.doi.org/10.1371/journal.pone.0236474 |