Cargando…

An endothelial rejection line following Descemet stripping automated endothelial keratoplasty

BACKGROUND: The endothelial rejection line is rarely seen after Descemet stripping automated endothelial keratoplasties (DSAEKs). Here, we present a case of endothelial graft rejection with an endothelial rejection line occurring 1 year after the procedure. CASE PRESENTATION: A 58-year-old female pr...

Descripción completa

Detalles Bibliográficos
Autores principales: Alkhalifah, Muhannad, Alqahtani, Bader, Almulhim, Abdulmohsen, Alsarhani, Waleed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7392701/
https://www.ncbi.nlm.nih.gov/pubmed/32727405
http://dx.doi.org/10.1186/s12886-020-01575-x