Cargando…

Anatomic Total Hip Component Position Is More Reproducible With the Direct Anterior Approach Using Intraoperative Fluoroscopy

BACKGROUND: Total hip arthroplasty (THA) has demonstrated excellent results regardless of the surgical approach. However, the approach used may be a factor in final positioning of implants. We hypothesized that the direct anterior approach (DAA) with fluoroscopy would be associated with more anatomi...

Descripción completa

Detalles Bibliográficos
Autores principales: Martin, J. Ryan, Masonis, John L., Mason, J. Bohannon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7490589/
https://www.ncbi.nlm.nih.gov/pubmed/32964086
http://dx.doi.org/10.1016/j.artd.2020.07.026
_version_ 1783582066038800384
author Martin, J. Ryan
Masonis, John L.
Mason, J. Bohannon
author_facet Martin, J. Ryan
Masonis, John L.
Mason, J. Bohannon
author_sort Martin, J. Ryan
collection PubMed
description BACKGROUND: Total hip arthroplasty (THA) has demonstrated excellent results regardless of the surgical approach. However, the approach used may be a factor in final positioning of implants. We hypothesized that the direct anterior approach (DAA) with fluoroscopy would be associated with more anatomic implant positioning than the posterior approach (PA). METHODS: A retrospective review of 200 patients was performed. One hundred patients underwent THA utilizing the PA, and 100 patients, with the DAA. All patients had an anterior-posterior pelvis radiograph preoperatively and postoperatively with a magnification marker present to standardize each radiograph. Exclusion criteria included contralateral THA or any pelvic or femoral deformity. RESULTS: Preoperative radiographs demonstrated identical cohorts with respect to leg length, femoral offset, and total offset. Postoperatively, the DAA achieved more accurate anatomic restoration of leg length (1.6 mm vs 5.5 mm; P < .0001), femoral offset (4.8 mm vs 9.3 mm; P < .0001), and total offset (0.5 mm vs 4.7 mm; P < .0001) compared with the PA. Ideal cup abduction and anteversion were significantly superior to the DAA (96% vs 78%, P = .0002, and 69% vs 24%, P < .0001, respectively). CONCLUSIONS: This study is the first to compare anatomic implant positioning between patients undergoing THA with these 2 approaches. All parameters were significantly closer to anatomic implant positioning with the DAA. There are at least 2 potential explanations for this: (1) The DAA implant positioning was performed under fluoroscopic guidance, whereas the PA was not. (2) The PA disrupts the posterior capsule and external rotators, and therefore, increased offset or leg length may be necessary to achieve comparable hip stability with the DAA.
format Online
Article
Text
id pubmed-7490589
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-74905892020-09-21 Anatomic Total Hip Component Position Is More Reproducible With the Direct Anterior Approach Using Intraoperative Fluoroscopy Martin, J. Ryan Masonis, John L. Mason, J. Bohannon Arthroplast Today Original Research BACKGROUND: Total hip arthroplasty (THA) has demonstrated excellent results regardless of the surgical approach. However, the approach used may be a factor in final positioning of implants. We hypothesized that the direct anterior approach (DAA) with fluoroscopy would be associated with more anatomic implant positioning than the posterior approach (PA). METHODS: A retrospective review of 200 patients was performed. One hundred patients underwent THA utilizing the PA, and 100 patients, with the DAA. All patients had an anterior-posterior pelvis radiograph preoperatively and postoperatively with a magnification marker present to standardize each radiograph. Exclusion criteria included contralateral THA or any pelvic or femoral deformity. RESULTS: Preoperative radiographs demonstrated identical cohorts with respect to leg length, femoral offset, and total offset. Postoperatively, the DAA achieved more accurate anatomic restoration of leg length (1.6 mm vs 5.5 mm; P < .0001), femoral offset (4.8 mm vs 9.3 mm; P < .0001), and total offset (0.5 mm vs 4.7 mm; P < .0001) compared with the PA. Ideal cup abduction and anteversion were significantly superior to the DAA (96% vs 78%, P = .0002, and 69% vs 24%, P < .0001, respectively). CONCLUSIONS: This study is the first to compare anatomic implant positioning between patients undergoing THA with these 2 approaches. All parameters were significantly closer to anatomic implant positioning with the DAA. There are at least 2 potential explanations for this: (1) The DAA implant positioning was performed under fluoroscopic guidance, whereas the PA was not. (2) The PA disrupts the posterior capsule and external rotators, and therefore, increased offset or leg length may be necessary to achieve comparable hip stability with the DAA. Elsevier 2020-09-08 /pmc/articles/PMC7490589/ /pubmed/32964086 http://dx.doi.org/10.1016/j.artd.2020.07.026 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Martin, J. Ryan
Masonis, John L.
Mason, J. Bohannon
Anatomic Total Hip Component Position Is More Reproducible With the Direct Anterior Approach Using Intraoperative Fluoroscopy
title Anatomic Total Hip Component Position Is More Reproducible With the Direct Anterior Approach Using Intraoperative Fluoroscopy
title_full Anatomic Total Hip Component Position Is More Reproducible With the Direct Anterior Approach Using Intraoperative Fluoroscopy
title_fullStr Anatomic Total Hip Component Position Is More Reproducible With the Direct Anterior Approach Using Intraoperative Fluoroscopy
title_full_unstemmed Anatomic Total Hip Component Position Is More Reproducible With the Direct Anterior Approach Using Intraoperative Fluoroscopy
title_short Anatomic Total Hip Component Position Is More Reproducible With the Direct Anterior Approach Using Intraoperative Fluoroscopy
title_sort anatomic total hip component position is more reproducible with the direct anterior approach using intraoperative fluoroscopy
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7490589/
https://www.ncbi.nlm.nih.gov/pubmed/32964086
http://dx.doi.org/10.1016/j.artd.2020.07.026
work_keys_str_mv AT martinjryan anatomictotalhipcomponentpositionismorereproduciblewiththedirectanteriorapproachusingintraoperativefluoroscopy
AT masonisjohnl anatomictotalhipcomponentpositionismorereproduciblewiththedirectanteriorapproachusingintraoperativefluoroscopy
AT masonjbohannon anatomictotalhipcomponentpositionismorereproduciblewiththedirectanteriorapproachusingintraoperativefluoroscopy