Cargando…

Direct analysis in real time-mass spectrometry for rapid quantification of five anti-arrhythmic drugs in human serum: application to therapeutic drug monitoring

Therapeutic drug monitoring (TDM) is necessary for the optimal administration of anti-arrhythmic drugs in the treatment of heart arrhythmia. The present study aimed to develop and validate a direct analysis in real time tandem mass spectrometry (DART–MS/MS) method for the rapid and simultaneous dete...

Descripción completa

Detalles Bibliográficos
Autores principales: Gui, Yuzhou, Lu, Youli, Li, Shuijun, Zhang, Mengqi, Duan, Xiaokun, Liu, Charles C., Jia, Jingying, Liu, Gangyi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7511339/
https://www.ncbi.nlm.nih.gov/pubmed/32968164
http://dx.doi.org/10.1038/s41598-020-72490-w
_version_ 1783585946544898048
author Gui, Yuzhou
Lu, Youli
Li, Shuijun
Zhang, Mengqi
Duan, Xiaokun
Liu, Charles C.
Jia, Jingying
Liu, Gangyi
author_facet Gui, Yuzhou
Lu, Youli
Li, Shuijun
Zhang, Mengqi
Duan, Xiaokun
Liu, Charles C.
Jia, Jingying
Liu, Gangyi
author_sort Gui, Yuzhou
collection PubMed
description Therapeutic drug monitoring (TDM) is necessary for the optimal administration of anti-arrhythmic drugs in the treatment of heart arrhythmia. The present study aimed to develop and validate a direct analysis in real time tandem mass spectrometry (DART–MS/MS) method for the rapid and simultaneous determination of five anti-arrhythmic drugs (metoprolol, diltiazem, amiodarone, propafenone, and verapamil) and one metabolite (5-hydroxy(OH)-propafenone) in human serum. After the addition of isotope-labeled internal standards and protein precipitation with acetonitrile, anti-arrhythmic drugs were ionized by DART in positive mode followed by multiple reaction monitoring (MRM) detection. The use of DART–MS/MS avoided the need for chromatographic separation and allowed rapid and ultrahigh throughput analysis of anti-arrhythmic drugs in a total run time of 30 s per sample. The DART–MS/MS method yielded satisfactory linearity (R(2) ≥ 0.9906), accuracy (86.1–109.9%), and precision (≤ 14.3%) with minimal effect of biological matrixes. The method was successfully applied to analyzing 30 clinical TDM samples. The relative error (RE) of the concentrations obtained by DART–MS/MS and liquid chromatography-tandem mass spectrometry (LC–MS/MS) was within ± 13%. This work highlights the potential usefulness of DART for the rapid quantitative analysis of anti-arrhythmic drugs in human serum and gives rapid feedback in the clinical TDM practices.
format Online
Article
Text
id pubmed-7511339
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-75113392020-09-24 Direct analysis in real time-mass spectrometry for rapid quantification of five anti-arrhythmic drugs in human serum: application to therapeutic drug monitoring Gui, Yuzhou Lu, Youli Li, Shuijun Zhang, Mengqi Duan, Xiaokun Liu, Charles C. Jia, Jingying Liu, Gangyi Sci Rep Article Therapeutic drug monitoring (TDM) is necessary for the optimal administration of anti-arrhythmic drugs in the treatment of heart arrhythmia. The present study aimed to develop and validate a direct analysis in real time tandem mass spectrometry (DART–MS/MS) method for the rapid and simultaneous determination of five anti-arrhythmic drugs (metoprolol, diltiazem, amiodarone, propafenone, and verapamil) and one metabolite (5-hydroxy(OH)-propafenone) in human serum. After the addition of isotope-labeled internal standards and protein precipitation with acetonitrile, anti-arrhythmic drugs were ionized by DART in positive mode followed by multiple reaction monitoring (MRM) detection. The use of DART–MS/MS avoided the need for chromatographic separation and allowed rapid and ultrahigh throughput analysis of anti-arrhythmic drugs in a total run time of 30 s per sample. The DART–MS/MS method yielded satisfactory linearity (R(2) ≥ 0.9906), accuracy (86.1–109.9%), and precision (≤ 14.3%) with minimal effect of biological matrixes. The method was successfully applied to analyzing 30 clinical TDM samples. The relative error (RE) of the concentrations obtained by DART–MS/MS and liquid chromatography-tandem mass spectrometry (LC–MS/MS) was within ± 13%. This work highlights the potential usefulness of DART for the rapid quantitative analysis of anti-arrhythmic drugs in human serum and gives rapid feedback in the clinical TDM practices. Nature Publishing Group UK 2020-09-23 /pmc/articles/PMC7511339/ /pubmed/32968164 http://dx.doi.org/10.1038/s41598-020-72490-w Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Gui, Yuzhou
Lu, Youli
Li, Shuijun
Zhang, Mengqi
Duan, Xiaokun
Liu, Charles C.
Jia, Jingying
Liu, Gangyi
Direct analysis in real time-mass spectrometry for rapid quantification of five anti-arrhythmic drugs in human serum: application to therapeutic drug monitoring
title Direct analysis in real time-mass spectrometry for rapid quantification of five anti-arrhythmic drugs in human serum: application to therapeutic drug monitoring
title_full Direct analysis in real time-mass spectrometry for rapid quantification of five anti-arrhythmic drugs in human serum: application to therapeutic drug monitoring
title_fullStr Direct analysis in real time-mass spectrometry for rapid quantification of five anti-arrhythmic drugs in human serum: application to therapeutic drug monitoring
title_full_unstemmed Direct analysis in real time-mass spectrometry for rapid quantification of five anti-arrhythmic drugs in human serum: application to therapeutic drug monitoring
title_short Direct analysis in real time-mass spectrometry for rapid quantification of five anti-arrhythmic drugs in human serum: application to therapeutic drug monitoring
title_sort direct analysis in real time-mass spectrometry for rapid quantification of five anti-arrhythmic drugs in human serum: application to therapeutic drug monitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7511339/
https://www.ncbi.nlm.nih.gov/pubmed/32968164
http://dx.doi.org/10.1038/s41598-020-72490-w
work_keys_str_mv AT guiyuzhou directanalysisinrealtimemassspectrometryforrapidquantificationoffiveantiarrhythmicdrugsinhumanserumapplicationtotherapeuticdrugmonitoring
AT luyouli directanalysisinrealtimemassspectrometryforrapidquantificationoffiveantiarrhythmicdrugsinhumanserumapplicationtotherapeuticdrugmonitoring
AT lishuijun directanalysisinrealtimemassspectrometryforrapidquantificationoffiveantiarrhythmicdrugsinhumanserumapplicationtotherapeuticdrugmonitoring
AT zhangmengqi directanalysisinrealtimemassspectrometryforrapidquantificationoffiveantiarrhythmicdrugsinhumanserumapplicationtotherapeuticdrugmonitoring
AT duanxiaokun directanalysisinrealtimemassspectrometryforrapidquantificationoffiveantiarrhythmicdrugsinhumanserumapplicationtotherapeuticdrugmonitoring
AT liucharlesc directanalysisinrealtimemassspectrometryforrapidquantificationoffiveantiarrhythmicdrugsinhumanserumapplicationtotherapeuticdrugmonitoring
AT jiajingying directanalysisinrealtimemassspectrometryforrapidquantificationoffiveantiarrhythmicdrugsinhumanserumapplicationtotherapeuticdrugmonitoring
AT liugangyi directanalysisinrealtimemassspectrometryforrapidquantificationoffiveantiarrhythmicdrugsinhumanserumapplicationtotherapeuticdrugmonitoring