Successful application of the snare technique for the deployment of the proximal portion of a Zenith Alpha Thoracic Endovascular Graft: a case report
BACKGROUND: Open surgery can be required or even fatal if incomplete deployment of stent graft (SG) occurs. We herein report the first case in which a snare was successfully used to perform endovascular therapeutic troubleshooting on the proximal portion of a Zenith Alpha thoracic endovascular graft...