Cargando…
The measurement of KRAS G12 mutants using multiplexed selected reaction monitoring and ion mobility mass spectrometry
RATIONALE: There is a considerable clinical demand to determine key mutations in genes involved with cancer which necessitates the deployment of highly specific and robust analytical methods. Multiplex liquid chromatography with selected reaction monitoring (LC/SRM) assays offer the ability to achie...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7539944/ https://www.ncbi.nlm.nih.gov/pubmed/31800120 http://dx.doi.org/10.1002/rcm.8657 |
_version_ | 1783591118953250816 |
---|---|
author | Norman, Rachel L Singh, Rajinder Langridge, James I. Ng, Leong L. Jones, Donald J.L. |
author_facet | Norman, Rachel L Singh, Rajinder Langridge, James I. Ng, Leong L. Jones, Donald J.L. |
author_sort | Norman, Rachel L |
collection | PubMed |
description | RATIONALE: There is a considerable clinical demand to determine key mutations in genes involved with cancer which necessitates the deployment of highly specific and robust analytical methods. Multiplex liquid chromatography with selected reaction monitoring (LC/SRM) assays offer the ability to achieve quantitation down to levels expected to be present in clinical samples. Ion mobility mass spectrometry (IMS/MS) assays can provide increased peak capacity and hence separation in an extremely short time frame, and in addition provide physicochemical data regarding the collision cross‐section of an analyte which can be used in conjunction with the m/z value of an ion to increase detection specificity. METHODS: For LC/SRM, unlabelled peptides and corresponding stable‐isotope‐labelled standards were spiked into digested human plasma and analysed using ultrahigh‐performance liquid chromatography (UHPLC) coupled to a triple quadrupole mass spectrometer to enable the generation of analyte‐specific calibration lines. Synthetic unlabelled peptides were infused into a Synapt G2 mass spectrometer for travelling wave ion mobility separation and (TW)CCS(N2) values were derived from comparison with previously generated (TW)CCS(N2) calibration values. RESULTS: Linear calibration lines (0.125 to 25 fmol/μL) were established for each of the KRAS peptides. UHPLC separated the peptides and hence enabled them to be split into different retention time functions/windows. This separation enabled detection of three or four transitions for each light and heavy peptide with at least 10 points per peak for accurate quantitation. All six KRAS G12 peptides were separated using IMS/MS, enabling precise (TW)CCS(N2) values to be determined. Although some of the G12 peptides chromatographically co‐eluted, all the peptides were distinguished by m/z, retention time and/or drift time. CONCLUSIONS: This study advocates that LC/SRM and IMS/MS could both be used to identify single amino acid substitutions in KRAS as an alternative to commonly used methods such as circulating tumour DNA analysis. |
format | Online Article Text |
id | pubmed-7539944 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-75399442020-10-09 The measurement of KRAS G12 mutants using multiplexed selected reaction monitoring and ion mobility mass spectrometry Norman, Rachel L Singh, Rajinder Langridge, James I. Ng, Leong L. Jones, Donald J.L. Rapid Commun Mass Spectrom Dai Games RATIONALE: There is a considerable clinical demand to determine key mutations in genes involved with cancer which necessitates the deployment of highly specific and robust analytical methods. Multiplex liquid chromatography with selected reaction monitoring (LC/SRM) assays offer the ability to achieve quantitation down to levels expected to be present in clinical samples. Ion mobility mass spectrometry (IMS/MS) assays can provide increased peak capacity and hence separation in an extremely short time frame, and in addition provide physicochemical data regarding the collision cross‐section of an analyte which can be used in conjunction with the m/z value of an ion to increase detection specificity. METHODS: For LC/SRM, unlabelled peptides and corresponding stable‐isotope‐labelled standards were spiked into digested human plasma and analysed using ultrahigh‐performance liquid chromatography (UHPLC) coupled to a triple quadrupole mass spectrometer to enable the generation of analyte‐specific calibration lines. Synthetic unlabelled peptides were infused into a Synapt G2 mass spectrometer for travelling wave ion mobility separation and (TW)CCS(N2) values were derived from comparison with previously generated (TW)CCS(N2) calibration values. RESULTS: Linear calibration lines (0.125 to 25 fmol/μL) were established for each of the KRAS peptides. UHPLC separated the peptides and hence enabled them to be split into different retention time functions/windows. This separation enabled detection of three or four transitions for each light and heavy peptide with at least 10 points per peak for accurate quantitation. All six KRAS G12 peptides were separated using IMS/MS, enabling precise (TW)CCS(N2) values to be determined. Although some of the G12 peptides chromatographically co‐eluted, all the peptides were distinguished by m/z, retention time and/or drift time. CONCLUSIONS: This study advocates that LC/SRM and IMS/MS could both be used to identify single amino acid substitutions in KRAS as an alternative to commonly used methods such as circulating tumour DNA analysis. John Wiley and Sons Inc. 2020-02-14 2020-09 /pmc/articles/PMC7539944/ /pubmed/31800120 http://dx.doi.org/10.1002/rcm.8657 Text en © 2019 The Authors. Rapid Communications in Mass Spectrometry published by John Wiley & Sons Ltd This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Dai Games Norman, Rachel L Singh, Rajinder Langridge, James I. Ng, Leong L. Jones, Donald J.L. The measurement of KRAS G12 mutants using multiplexed selected reaction monitoring and ion mobility mass spectrometry |
title | The measurement of KRAS G12 mutants using multiplexed selected reaction monitoring and ion mobility mass spectrometry |
title_full | The measurement of KRAS G12 mutants using multiplexed selected reaction monitoring and ion mobility mass spectrometry |
title_fullStr | The measurement of KRAS G12 mutants using multiplexed selected reaction monitoring and ion mobility mass spectrometry |
title_full_unstemmed | The measurement of KRAS G12 mutants using multiplexed selected reaction monitoring and ion mobility mass spectrometry |
title_short | The measurement of KRAS G12 mutants using multiplexed selected reaction monitoring and ion mobility mass spectrometry |
title_sort | measurement of kras g12 mutants using multiplexed selected reaction monitoring and ion mobility mass spectrometry |
topic | Dai Games |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7539944/ https://www.ncbi.nlm.nih.gov/pubmed/31800120 http://dx.doi.org/10.1002/rcm.8657 |
work_keys_str_mv | AT normanrachell themeasurementofkrasg12mutantsusingmultiplexedselectedreactionmonitoringandionmobilitymassspectrometry AT singhrajinder themeasurementofkrasg12mutantsusingmultiplexedselectedreactionmonitoringandionmobilitymassspectrometry AT langridgejamesi themeasurementofkrasg12mutantsusingmultiplexedselectedreactionmonitoringandionmobilitymassspectrometry AT ngleongl themeasurementofkrasg12mutantsusingmultiplexedselectedreactionmonitoringandionmobilitymassspectrometry AT jonesdonaldjl themeasurementofkrasg12mutantsusingmultiplexedselectedreactionmonitoringandionmobilitymassspectrometry AT normanrachell measurementofkrasg12mutantsusingmultiplexedselectedreactionmonitoringandionmobilitymassspectrometry AT singhrajinder measurementofkrasg12mutantsusingmultiplexedselectedreactionmonitoringandionmobilitymassspectrometry AT langridgejamesi measurementofkrasg12mutantsusingmultiplexedselectedreactionmonitoringandionmobilitymassspectrometry AT ngleongl measurementofkrasg12mutantsusingmultiplexedselectedreactionmonitoringandionmobilitymassspectrometry AT jonesdonaldjl measurementofkrasg12mutantsusingmultiplexedselectedreactionmonitoringandionmobilitymassspectrometry |