Nalaganje...

Quantitative analysis of 11‐dehydrocorticosterone and corticosterone for preclinical studies by liquid chromatography/triple quadrupole mass spectrometry

RATIONALE: The activity of the glucocorticoid activating enzyme 11β‐hydroxysteroid dehydrogenase type‐1 (11βHSD1) is altered in diseases such as obesity, inflammation and psychiatric disorders. In rodents 11βHSD1 converts inert 11‐dehydrocorticosterone (11‐DHC) into the active form, corticosterone (...

Popoln opis

Bibliografske podrobnosti
Autores principales: Verma, Manu, Sooy, Karen, Just, George, Nixon, Mark, Morgan, Ruth, Andrew, Ruth, Chapman, Karen E., Homer, Natalie Z.M.
Format: Online Artículo Texto
Jezik:English
Izdano: John Wiley and Sons Inc. 2020
Teme:
Online dostop:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7540072/
https://www.ncbi.nlm.nih.gov/pubmed/31677354
http://dx.doi.org/10.1002/rcm.8610
_version_ 1783591146993221632
author Verma, Manu
Sooy, Karen
Just, George
Nixon, Mark
Morgan, Ruth
Andrew, Ruth
Chapman, Karen E.
Homer, Natalie Z.M.
author_facet Verma, Manu
Sooy, Karen
Just, George
Nixon, Mark
Morgan, Ruth
Andrew, Ruth
Chapman, Karen E.
Homer, Natalie Z.M.
author_sort Verma, Manu
collection PubMed
description RATIONALE: The activity of the glucocorticoid activating enzyme 11β‐hydroxysteroid dehydrogenase type‐1 (11βHSD1) is altered in diseases such as obesity, inflammation and psychiatric disorders. In rodents 11βHSD1 converts inert 11‐dehydrocorticosterone (11‐DHC) into the active form, corticosterone (CORT). A sensitive, specific liquid chromatography/tandem mass spectrometry method was sought to simultaneously quantify total 11‐DHC and total and free CORT in murine plasma for simple assessment of 11βHSD1 activity in murine models. METHODS: Mass spectrometry parameters were optimised and a method for the chromatographic separation of CORT and 11‐DHC was developed. Murine plasma was prepared by 10:1 chloroform liquid–liquid extraction (LLE) for analysis. Limits of quantitation (LOQs), linearity and other method criteria were assessed, according to bioanalytical method validation guidelines. RESULTS: Reliable separation of 11‐DHC and CORT was achieved using an ACE Excel 2 C18‐AR (2.1 × 150 mm; 2 μm) fused core column at 25°C, with an acidified water/acetonitrile gradient over 10 min. Analytes were detected by multiple reaction monitoring after positive electrospray ionisation (m/z 345.1.1 ➔ 121.2, m/z 347.1 ➔ 121.1 for 11‐DHC and CORT, respectively). The LOQs were 0.25 and 0.20 ng/mL for 11‐DHC and CORT, respectively. CONCLUSIONS: This LC/MS method is suitable for the reliable analysis of 11‐DHC and CORT following simple LLE of murine plasma, bringing preclinical analysis in line with recommendations for clinical endocrinology and biochemistry.
format Online
Article
Text
id pubmed-7540072
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-75400722020-10-09 Quantitative analysis of 11‐dehydrocorticosterone and corticosterone for preclinical studies by liquid chromatography/triple quadrupole mass spectrometry Verma, Manu Sooy, Karen Just, George Nixon, Mark Morgan, Ruth Andrew, Ruth Chapman, Karen E. Homer, Natalie Z.M. Rapid Commun Mass Spectrom Dai Games RATIONALE: The activity of the glucocorticoid activating enzyme 11β‐hydroxysteroid dehydrogenase type‐1 (11βHSD1) is altered in diseases such as obesity, inflammation and psychiatric disorders. In rodents 11βHSD1 converts inert 11‐dehydrocorticosterone (11‐DHC) into the active form, corticosterone (CORT). A sensitive, specific liquid chromatography/tandem mass spectrometry method was sought to simultaneously quantify total 11‐DHC and total and free CORT in murine plasma for simple assessment of 11βHSD1 activity in murine models. METHODS: Mass spectrometry parameters were optimised and a method for the chromatographic separation of CORT and 11‐DHC was developed. Murine plasma was prepared by 10:1 chloroform liquid–liquid extraction (LLE) for analysis. Limits of quantitation (LOQs), linearity and other method criteria were assessed, according to bioanalytical method validation guidelines. RESULTS: Reliable separation of 11‐DHC and CORT was achieved using an ACE Excel 2 C18‐AR (2.1 × 150 mm; 2 μm) fused core column at 25°C, with an acidified water/acetonitrile gradient over 10 min. Analytes were detected by multiple reaction monitoring after positive electrospray ionisation (m/z 345.1.1 ➔ 121.2, m/z 347.1 ➔ 121.1 for 11‐DHC and CORT, respectively). The LOQs were 0.25 and 0.20 ng/mL for 11‐DHC and CORT, respectively. CONCLUSIONS: This LC/MS method is suitable for the reliable analysis of 11‐DHC and CORT following simple LLE of murine plasma, bringing preclinical analysis in line with recommendations for clinical endocrinology and biochemistry. John Wiley and Sons Inc. 2020-02-11 2020-09 /pmc/articles/PMC7540072/ /pubmed/31677354 http://dx.doi.org/10.1002/rcm.8610 Text en © 2019 The Authors. Rapid Communications in Mass Spectrometry published by John Wiley & Sons Ltd This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Dai Games
Verma, Manu
Sooy, Karen
Just, George
Nixon, Mark
Morgan, Ruth
Andrew, Ruth
Chapman, Karen E.
Homer, Natalie Z.M.
Quantitative analysis of 11‐dehydrocorticosterone and corticosterone for preclinical studies by liquid chromatography/triple quadrupole mass spectrometry
title Quantitative analysis of 11‐dehydrocorticosterone and corticosterone for preclinical studies by liquid chromatography/triple quadrupole mass spectrometry
title_full Quantitative analysis of 11‐dehydrocorticosterone and corticosterone for preclinical studies by liquid chromatography/triple quadrupole mass spectrometry
title_fullStr Quantitative analysis of 11‐dehydrocorticosterone and corticosterone for preclinical studies by liquid chromatography/triple quadrupole mass spectrometry
title_full_unstemmed Quantitative analysis of 11‐dehydrocorticosterone and corticosterone for preclinical studies by liquid chromatography/triple quadrupole mass spectrometry
title_short Quantitative analysis of 11‐dehydrocorticosterone and corticosterone for preclinical studies by liquid chromatography/triple quadrupole mass spectrometry
title_sort quantitative analysis of 11‐dehydrocorticosterone and corticosterone for preclinical studies by liquid chromatography/triple quadrupole mass spectrometry
topic Dai Games
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7540072/
https://www.ncbi.nlm.nih.gov/pubmed/31677354
http://dx.doi.org/10.1002/rcm.8610
work_keys_str_mv AT vermamanu quantitativeanalysisof11dehydrocorticosteroneandcorticosteroneforpreclinicalstudiesbyliquidchromatographytriplequadrupolemassspectrometry
AT sooykaren quantitativeanalysisof11dehydrocorticosteroneandcorticosteroneforpreclinicalstudiesbyliquidchromatographytriplequadrupolemassspectrometry
AT justgeorge quantitativeanalysisof11dehydrocorticosteroneandcorticosteroneforpreclinicalstudiesbyliquidchromatographytriplequadrupolemassspectrometry
AT nixonmark quantitativeanalysisof11dehydrocorticosteroneandcorticosteroneforpreclinicalstudiesbyliquidchromatographytriplequadrupolemassspectrometry
AT morganruth quantitativeanalysisof11dehydrocorticosteroneandcorticosteroneforpreclinicalstudiesbyliquidchromatographytriplequadrupolemassspectrometry
AT andrewruth quantitativeanalysisof11dehydrocorticosteroneandcorticosteroneforpreclinicalstudiesbyliquidchromatographytriplequadrupolemassspectrometry
AT chapmankarene quantitativeanalysisof11dehydrocorticosteroneandcorticosteroneforpreclinicalstudiesbyliquidchromatographytriplequadrupolemassspectrometry
AT homernataliezm quantitativeanalysisof11dehydrocorticosteroneandcorticosteroneforpreclinicalstudiesbyliquidchromatographytriplequadrupolemassspectrometry