Reducing Inpatient Hypoglycemia in the General Wards Using Real-time Continuous Glucose Monitoring: The Glucose Telemetry System, a Randomized Clinical Trial

OBJECTIVE: Use of real-time continuous glucose monitoring (RT-CGM) systems in the inpatient setting is considered investigational. The objective of this study was to evaluate whether RT-CGM, using the glucose telemetry system (GTS), can prevent hypoglycemia in the general wards. RESEARCH DESIGN AND...

Descripción completa

Detalles Bibliográficos
Autores principales: Singh, Lakshmi G., Satyarengga, Medha, Marcano, Isabel, Scott, William H., Pinault, Lillian F., Feng, Zhaoyong, Sorkin, John D., Umpierrez, Guillermo E., Spanakis, Elias K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Diabetes Association 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7576426/
https://www.ncbi.nlm.nih.gov/pubmed/32759361
http://dx.doi.org/10.2337/dc20-0840