Cargando…

Occupational Exposure to Fine Particulate Matter (PM(4) and PM(2.5)) during Hand-Made Cookware Operation: Personal, Indoor and Outdoor Levels

(1) Exposure of informal artisanal cookware makers to fine particles has not yet been characterized. The aim of this study was to characterize occupational exposure to fine particulate matter (PM(4) and PM(2.5)) levels and fine particulate matter (PM(2.5)) elemental components; (2) Artisanal cookwar...

Descripción completa

Detalles Bibliográficos
Autores principales: Shezi, Busisiwe, Mathee, Angela, Cele, Nokulunga, Ndabandaba, Sipho, Street, Renee A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7602743/
https://www.ncbi.nlm.nih.gov/pubmed/33081113
http://dx.doi.org/10.3390/ijerph17207522
_version_ 1783603754801561600
author Shezi, Busisiwe
Mathee, Angela
Cele, Nokulunga
Ndabandaba, Sipho
Street, Renee A.
author_facet Shezi, Busisiwe
Mathee, Angela
Cele, Nokulunga
Ndabandaba, Sipho
Street, Renee A.
author_sort Shezi, Busisiwe
collection PubMed
description (1) Exposure of informal artisanal cookware makers to fine particles has not yet been characterized. The aim of this study was to characterize occupational exposure to fine particulate matter (PM(4) and PM(2.5)) levels and fine particulate matter (PM(2.5)) elemental components; (2) Artisanal cookware makers were recruited from five cookware making sites. Exposure to fine particulate matter was measured for 17 male participants. SidePak personal aerosol monitors (AM520) were used to measure personal exposure to PM(4), while a DustTrak monitor and an E-sampler were used to assess indoor and outdoor PM(2.5) levels, respectively. A questionnaire was administered to capture information on demographic characteristics. The chemical characterization of indoor and outdoor PM(2.5) filter mass was conducted using Wavelength Dispersive X-ray Fluorescence. Time series record of 15-min averages for indoor and outdoor PM(2.5) levels were assessed; (3) The median (range) was 124 µg/m(3) (23−100,000), 64 µg/m(3) (1−6097) and 12 µg/m(3) (4−1178), respectively, for personal PM(4), indoor and outdoor PM(2.5). The highest levels for many of the elemental components of PM(2.5) were found in the outdoor PM(2.5) filter mass and (4). The information generated during this study may assist in extending occupational health and safety strategies to artisanal cookware makers and developing targeted prevention initiatives.
format Online
Article
Text
id pubmed-7602743
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-76027432020-11-01 Occupational Exposure to Fine Particulate Matter (PM(4) and PM(2.5)) during Hand-Made Cookware Operation: Personal, Indoor and Outdoor Levels Shezi, Busisiwe Mathee, Angela Cele, Nokulunga Ndabandaba, Sipho Street, Renee A. Int J Environ Res Public Health Article (1) Exposure of informal artisanal cookware makers to fine particles has not yet been characterized. The aim of this study was to characterize occupational exposure to fine particulate matter (PM(4) and PM(2.5)) levels and fine particulate matter (PM(2.5)) elemental components; (2) Artisanal cookware makers were recruited from five cookware making sites. Exposure to fine particulate matter was measured for 17 male participants. SidePak personal aerosol monitors (AM520) were used to measure personal exposure to PM(4), while a DustTrak monitor and an E-sampler were used to assess indoor and outdoor PM(2.5) levels, respectively. A questionnaire was administered to capture information on demographic characteristics. The chemical characterization of indoor and outdoor PM(2.5) filter mass was conducted using Wavelength Dispersive X-ray Fluorescence. Time series record of 15-min averages for indoor and outdoor PM(2.5) levels were assessed; (3) The median (range) was 124 µg/m(3) (23−100,000), 64 µg/m(3) (1−6097) and 12 µg/m(3) (4−1178), respectively, for personal PM(4), indoor and outdoor PM(2.5). The highest levels for many of the elemental components of PM(2.5) were found in the outdoor PM(2.5) filter mass and (4). The information generated during this study may assist in extending occupational health and safety strategies to artisanal cookware makers and developing targeted prevention initiatives. MDPI 2020-10-16 2020-10 /pmc/articles/PMC7602743/ /pubmed/33081113 http://dx.doi.org/10.3390/ijerph17207522 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shezi, Busisiwe
Mathee, Angela
Cele, Nokulunga
Ndabandaba, Sipho
Street, Renee A.
Occupational Exposure to Fine Particulate Matter (PM(4) and PM(2.5)) during Hand-Made Cookware Operation: Personal, Indoor and Outdoor Levels
title Occupational Exposure to Fine Particulate Matter (PM(4) and PM(2.5)) during Hand-Made Cookware Operation: Personal, Indoor and Outdoor Levels
title_full Occupational Exposure to Fine Particulate Matter (PM(4) and PM(2.5)) during Hand-Made Cookware Operation: Personal, Indoor and Outdoor Levels
title_fullStr Occupational Exposure to Fine Particulate Matter (PM(4) and PM(2.5)) during Hand-Made Cookware Operation: Personal, Indoor and Outdoor Levels
title_full_unstemmed Occupational Exposure to Fine Particulate Matter (PM(4) and PM(2.5)) during Hand-Made Cookware Operation: Personal, Indoor and Outdoor Levels
title_short Occupational Exposure to Fine Particulate Matter (PM(4) and PM(2.5)) during Hand-Made Cookware Operation: Personal, Indoor and Outdoor Levels
title_sort occupational exposure to fine particulate matter (pm(4) and pm(2.5)) during hand-made cookware operation: personal, indoor and outdoor levels
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7602743/
https://www.ncbi.nlm.nih.gov/pubmed/33081113
http://dx.doi.org/10.3390/ijerph17207522
work_keys_str_mv AT shezibusisiwe occupationalexposuretofineparticulatematterpm4andpm25duringhandmadecookwareoperationpersonalindoorandoutdoorlevels
AT matheeangela occupationalexposuretofineparticulatematterpm4andpm25duringhandmadecookwareoperationpersonalindoorandoutdoorlevels
AT celenokulunga occupationalexposuretofineparticulatematterpm4andpm25duringhandmadecookwareoperationpersonalindoorandoutdoorlevels
AT ndabandabasipho occupationalexposuretofineparticulatematterpm4andpm25duringhandmadecookwareoperationpersonalindoorandoutdoorlevels
AT streetreneea occupationalexposuretofineparticulatematterpm4andpm25duringhandmadecookwareoperationpersonalindoorandoutdoorlevels