Cargando…

LC-MS/MS based detection of circulating proinsulin derived peptides in patients with altered pancreatic beta cell function

Routine immunoassays for insulin and C-peptide have the potential to cross-react with partially processed proinsulin products, although in healthy patients these are present at such low levels that the interference is insignificant. Elevated concentrations of proinsulin and des-31,32 proinsulin aris...

Descripción completa

Detalles Bibliográficos
Autores principales: Foreman, Rachel E, Meek, Claire L, Roberts, Geoffrey P, George, Amy L, Reimann, Frank, Gribble, Fiona M, Kay, Richard G
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7614196/
https://www.ncbi.nlm.nih.gov/pubmed/36242807
http://dx.doi.org/10.1016/j.jchromb.2022.123482
_version_ 1783605576214773760
author Foreman, Rachel E
Meek, Claire L
Roberts, Geoffrey P
George, Amy L
Reimann, Frank
Gribble, Fiona M
Kay, Richard G
author_facet Foreman, Rachel E
Meek, Claire L
Roberts, Geoffrey P
George, Amy L
Reimann, Frank
Gribble, Fiona M
Kay, Richard G
author_sort Foreman, Rachel E
collection PubMed
description Routine immunoassays for insulin and C-peptide have the potential to cross-react with partially processed proinsulin products, although in healthy patients these are present at such low levels that the interference is insignificant. Elevated concentrations of proinsulin and des-31,32 proinsulin arising from pathological conditions, or injected insulin analogues, however can cause significant assay interferences, complicating interpretation. Clinical diagnosis and management therefore sometimes require methods that can distinguish true insulin and C-peptide from partially processed proinsulin or injected insulin analogues. In this scenario, the high specificity of mass spectrometric analysis offers potential benefit for patient care. A high throughput targeted LC-MS/MS method was developed as a fit for purpose investigation of insulin, insulin analogues, C-peptide and proinsulin processing intermediates in plasma samples from different patient groups. Using calibration standards and bovine insulin as an internal standard, absolute concentrations of insulin and C-peptide were quantified across a nominal human plasma postprandial range and correlated strongly with immunoassay-based measurements. The ability to distinguish between insulin, insulin analogues and proinsulin intermediates in a single extraction is an improvement over existing immunological based techniques, offering the advantage of exact identification of the species being measured. The method promises to aid in the detection of circulating peptides which have previously been overlooked but may interfere with standard insulin and C-peptide immunoassays.
format Online
Article
Text
id pubmed-7614196
institution National Center for Biotechnology Information
language English
publishDate 2022
record_format MEDLINE/PubMed
spelling pubmed-76141962023-02-17 LC-MS/MS based detection of circulating proinsulin derived peptides in patients with altered pancreatic beta cell function Foreman, Rachel E Meek, Claire L Roberts, Geoffrey P George, Amy L Reimann, Frank Gribble, Fiona M Kay, Richard G J Chromatogr B Analyt Technol Biomed Life Sci Article Routine immunoassays for insulin and C-peptide have the potential to cross-react with partially processed proinsulin products, although in healthy patients these are present at such low levels that the interference is insignificant. Elevated concentrations of proinsulin and des-31,32 proinsulin arising from pathological conditions, or injected insulin analogues, however can cause significant assay interferences, complicating interpretation. Clinical diagnosis and management therefore sometimes require methods that can distinguish true insulin and C-peptide from partially processed proinsulin or injected insulin analogues. In this scenario, the high specificity of mass spectrometric analysis offers potential benefit for patient care. A high throughput targeted LC-MS/MS method was developed as a fit for purpose investigation of insulin, insulin analogues, C-peptide and proinsulin processing intermediates in plasma samples from different patient groups. Using calibration standards and bovine insulin as an internal standard, absolute concentrations of insulin and C-peptide were quantified across a nominal human plasma postprandial range and correlated strongly with immunoassay-based measurements. The ability to distinguish between insulin, insulin analogues and proinsulin intermediates in a single extraction is an improvement over existing immunological based techniques, offering the advantage of exact identification of the species being measured. The method promises to aid in the detection of circulating peptides which have previously been overlooked but may interfere with standard insulin and C-peptide immunoassays. 2022-11-15 2022-10-05 /pmc/articles/PMC7614196/ /pubmed/36242807 http://dx.doi.org/10.1016/j.jchromb.2022.123482 Text en https://creativecommons.org/licenses/by/4.0/This work is licensed under a CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/) International license.
spellingShingle Article
Foreman, Rachel E
Meek, Claire L
Roberts, Geoffrey P
George, Amy L
Reimann, Frank
Gribble, Fiona M
Kay, Richard G
LC-MS/MS based detection of circulating proinsulin derived peptides in patients with altered pancreatic beta cell function
title LC-MS/MS based detection of circulating proinsulin derived peptides in patients with altered pancreatic beta cell function
title_full LC-MS/MS based detection of circulating proinsulin derived peptides in patients with altered pancreatic beta cell function
title_fullStr LC-MS/MS based detection of circulating proinsulin derived peptides in patients with altered pancreatic beta cell function
title_full_unstemmed LC-MS/MS based detection of circulating proinsulin derived peptides in patients with altered pancreatic beta cell function
title_short LC-MS/MS based detection of circulating proinsulin derived peptides in patients with altered pancreatic beta cell function
title_sort lc-ms/ms based detection of circulating proinsulin derived peptides in patients with altered pancreatic beta cell function
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7614196/
https://www.ncbi.nlm.nih.gov/pubmed/36242807
http://dx.doi.org/10.1016/j.jchromb.2022.123482
work_keys_str_mv AT foremanrachele lcmsmsbaseddetectionofcirculatingproinsulinderivedpeptidesinpatientswithalteredpancreaticbetacellfunction
AT meekclairel lcmsmsbaseddetectionofcirculatingproinsulinderivedpeptidesinpatientswithalteredpancreaticbetacellfunction
AT robertsgeoffreyp lcmsmsbaseddetectionofcirculatingproinsulinderivedpeptidesinpatientswithalteredpancreaticbetacellfunction
AT georgeamyl lcmsmsbaseddetectionofcirculatingproinsulinderivedpeptidesinpatientswithalteredpancreaticbetacellfunction
AT reimannfrank lcmsmsbaseddetectionofcirculatingproinsulinderivedpeptidesinpatientswithalteredpancreaticbetacellfunction
AT gribblefionam lcmsmsbaseddetectionofcirculatingproinsulinderivedpeptidesinpatientswithalteredpancreaticbetacellfunction
AT kayrichardg lcmsmsbaseddetectionofcirculatingproinsulinderivedpeptidesinpatientswithalteredpancreaticbetacellfunction