Cargando…
Successful Retrieval of a Stuck Guidewire by Guiding Catheter Lock Technique in Renal Artery Stenting
INTRODUCTION: The guiding catheter lock technique is a therapeutic technique to increase backup force of the guiding catheter in coronary artery interventions. SURGICAL TECHNIQUE: A 71 year old man presented with rapidly declining kidney function resulting from bilateral renal artery stenosis. Durin...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7691746/ https://www.ncbi.nlm.nih.gov/pubmed/33294882 http://dx.doi.org/10.1016/j.ejvsvf.2020.10.004 |