Cargando…
LC-MS based stability-indicating method for studying the degradation of lonidamine under physical and chemical stress conditions
BACKGROUND AND PURPOSE: Lonidamine is a hexokinase II inhibitor, works as an anticancer molecule, and is extensively explored in clinical trials. Limited information prevails about the stability-indicating methods which could determine the forced degradation of lonidamine under stressed conditions....
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7714013/ https://www.ncbi.nlm.nih.gov/pubmed/33312209 http://dx.doi.org/10.4103/1735-5362.293509 |
Sumario: | BACKGROUND AND PURPOSE: Lonidamine is a hexokinase II inhibitor, works as an anticancer molecule, and is extensively explored in clinical trials. Limited information prevails about the stability-indicating methods which could determine the forced degradation of lonidamine under stressed conditions. Hence, we report the use of a rapid, sensitive, reproducible, and highly accurate liquid chromatography and mass spectrometry method to analyze lonidamine degradation. EXPERIMENTAL APPROACH: The Xbridge BEH shield reverse phase C18 column (2.5 μm, 4.6 × 75 mm) using isocratic 50:50 water: acetonitrile with 0.1% formic acid can detect lonidamine with help of mass spectrometer in tandem with an ultraviolet (UV) detector at 260 nm wavelength. FINDINGS/ RESULTS: A linear curve with r(2) > 0.99 was obtained for tandem liquid chromatography-mass spectrometry (LC-MS)-UV based detections. This study demonstrated (in the present set up of isocratic elution) that LC-MS based detection has a relatively high sensitivity (S/N (10 ng/mL): 220 and S/N (20 ng/mL): 945) and accuracy at lower detection and quantitation levels, respectively. In addition to developing the LC-MS method, we also report that the current method is stability-indicating and shows that lonidamine gets degraded over time under all three stress conditions; acidic, basic, and oxidative. CONCLUSION AND IMPLICATIONS: LC-MS based quantitation of lonidamine proved to be a better method compared to high-performance liquid chromatography (HPLC)-UV detections for mapping lonidamine degradation. This is the first report on the stability-indicating method for studying the forced degradation of lonidamine using LC-MS method. |
---|