Cargando…

Successful use of an automated proning system to achieve prone positioning in a patient with severe ARDS requiring veno-venous ECMO

A morbidly obese middle aged woman in her 40's presented to another hospital with methicillin resistant staphylococcus aureus pneumonia and subsequently developed severe acute respiratory distress syndrome. Her oxygenation demonstrated no improvement with low tidal volume ventilation, paralysis...

Descripción completa

Detalles Bibliográficos
Autores principales: Lehr, Andrew L., Smith, Deane E., Toy, Bridget, Goldenberg, Ronald, Brosnahan, Shari B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7734294/
https://www.ncbi.nlm.nih.gov/pubmed/33335831
http://dx.doi.org/10.1016/j.rmcr.2020.101315