Cargando…

Rapid detection of Clostridium perfringens in food by loop-mediated isothermal amplification combined with a lateral flow biosensor

Clostridium perfringens is a key anaerobic pathogen causing food poisoning. Definitive detection by standard culture method is time-consuming and labor intensive. Current rapid commercial test kits are prohibitively expensive. It is thus necessary to develop rapid and cost-effective detection tool....

Descripción completa

Detalles Bibliográficos
Autores principales: Sridapan, Thanawat, Tangkawsakul, Wanida, Janvilisri, Tavan, Kiatpathomchai, Wansika, Dangtip, Sirintip, Ngamwongsatit, Natharin, Nacapricha, Duangjai, Ounjai, Puey, Chankhamhaengdecha, Surang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7790239/
https://www.ncbi.nlm.nih.gov/pubmed/33411848
http://dx.doi.org/10.1371/journal.pone.0245144
_version_ 1783633379609018368
author Sridapan, Thanawat
Tangkawsakul, Wanida
Janvilisri, Tavan
Kiatpathomchai, Wansika
Dangtip, Sirintip
Ngamwongsatit, Natharin
Nacapricha, Duangjai
Ounjai, Puey
Chankhamhaengdecha, Surang
author_facet Sridapan, Thanawat
Tangkawsakul, Wanida
Janvilisri, Tavan
Kiatpathomchai, Wansika
Dangtip, Sirintip
Ngamwongsatit, Natharin
Nacapricha, Duangjai
Ounjai, Puey
Chankhamhaengdecha, Surang
author_sort Sridapan, Thanawat
collection PubMed
description Clostridium perfringens is a key anaerobic pathogen causing food poisoning. Definitive detection by standard culture method is time-consuming and labor intensive. Current rapid commercial test kits are prohibitively expensive. It is thus necessary to develop rapid and cost-effective detection tool. Here, loop-mediated isothermal amplification (LAMP) in combination with a lateral-flow biosensor (LFB) was developed for visual inspection of C. perfringens-specific cpa gene. The specificity of the developed test was evaluated against 40 C. perfringens and 35 other bacterial strains, which showed no cross-reactivity, indicating 100% inclusivity and exclusivity. LAMP-LFB detection limit for artificially contaminated samples after enrichment for 16 h was 1–10 CFU/g sample, which was comparable to the commercial real-time PCR kit. The detection performance of LAMP-LFB was also compared to culture-based method using 95 food samples, which revealed the sensitivity (SE), specificity (SP) and Cohen's kappa coefficient (κ) of 88.0% (95% CI, 75.6%-95.4%), 95.5% (95% CI, 84.8%-99.4%) and 0.832 (95% CI, 0.721–0.943), respectively. Area under the receiver operating characteristic (ROC) curve was 0.918 (95% CI, 0.854–0.981), indicating LAMP-LFB as high relative accuracy test. In conclusion, LAMP-LFB assay is a low-cost qualitative method and easily available for routine detection of C. perfringens in food samples, which could serve as an alternative to commercial test kit.
format Online
Article
Text
id pubmed-7790239
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-77902392021-01-14 Rapid detection of Clostridium perfringens in food by loop-mediated isothermal amplification combined with a lateral flow biosensor Sridapan, Thanawat Tangkawsakul, Wanida Janvilisri, Tavan Kiatpathomchai, Wansika Dangtip, Sirintip Ngamwongsatit, Natharin Nacapricha, Duangjai Ounjai, Puey Chankhamhaengdecha, Surang PLoS One Research Article Clostridium perfringens is a key anaerobic pathogen causing food poisoning. Definitive detection by standard culture method is time-consuming and labor intensive. Current rapid commercial test kits are prohibitively expensive. It is thus necessary to develop rapid and cost-effective detection tool. Here, loop-mediated isothermal amplification (LAMP) in combination with a lateral-flow biosensor (LFB) was developed for visual inspection of C. perfringens-specific cpa gene. The specificity of the developed test was evaluated against 40 C. perfringens and 35 other bacterial strains, which showed no cross-reactivity, indicating 100% inclusivity and exclusivity. LAMP-LFB detection limit for artificially contaminated samples after enrichment for 16 h was 1–10 CFU/g sample, which was comparable to the commercial real-time PCR kit. The detection performance of LAMP-LFB was also compared to culture-based method using 95 food samples, which revealed the sensitivity (SE), specificity (SP) and Cohen's kappa coefficient (κ) of 88.0% (95% CI, 75.6%-95.4%), 95.5% (95% CI, 84.8%-99.4%) and 0.832 (95% CI, 0.721–0.943), respectively. Area under the receiver operating characteristic (ROC) curve was 0.918 (95% CI, 0.854–0.981), indicating LAMP-LFB as high relative accuracy test. In conclusion, LAMP-LFB assay is a low-cost qualitative method and easily available for routine detection of C. perfringens in food samples, which could serve as an alternative to commercial test kit. Public Library of Science 2021-01-07 /pmc/articles/PMC7790239/ /pubmed/33411848 http://dx.doi.org/10.1371/journal.pone.0245144 Text en © 2021 Sridapan et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Sridapan, Thanawat
Tangkawsakul, Wanida
Janvilisri, Tavan
Kiatpathomchai, Wansika
Dangtip, Sirintip
Ngamwongsatit, Natharin
Nacapricha, Duangjai
Ounjai, Puey
Chankhamhaengdecha, Surang
Rapid detection of Clostridium perfringens in food by loop-mediated isothermal amplification combined with a lateral flow biosensor
title Rapid detection of Clostridium perfringens in food by loop-mediated isothermal amplification combined with a lateral flow biosensor
title_full Rapid detection of Clostridium perfringens in food by loop-mediated isothermal amplification combined with a lateral flow biosensor
title_fullStr Rapid detection of Clostridium perfringens in food by loop-mediated isothermal amplification combined with a lateral flow biosensor
title_full_unstemmed Rapid detection of Clostridium perfringens in food by loop-mediated isothermal amplification combined with a lateral flow biosensor
title_short Rapid detection of Clostridium perfringens in food by loop-mediated isothermal amplification combined with a lateral flow biosensor
title_sort rapid detection of clostridium perfringens in food by loop-mediated isothermal amplification combined with a lateral flow biosensor
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7790239/
https://www.ncbi.nlm.nih.gov/pubmed/33411848
http://dx.doi.org/10.1371/journal.pone.0245144
work_keys_str_mv AT sridapanthanawat rapiddetectionofclostridiumperfringensinfoodbyloopmediatedisothermalamplificationcombinedwithalateralflowbiosensor
AT tangkawsakulwanida rapiddetectionofclostridiumperfringensinfoodbyloopmediatedisothermalamplificationcombinedwithalateralflowbiosensor
AT janvilisritavan rapiddetectionofclostridiumperfringensinfoodbyloopmediatedisothermalamplificationcombinedwithalateralflowbiosensor
AT kiatpathomchaiwansika rapiddetectionofclostridiumperfringensinfoodbyloopmediatedisothermalamplificationcombinedwithalateralflowbiosensor
AT dangtipsirintip rapiddetectionofclostridiumperfringensinfoodbyloopmediatedisothermalamplificationcombinedwithalateralflowbiosensor
AT ngamwongsatitnatharin rapiddetectionofclostridiumperfringensinfoodbyloopmediatedisothermalamplificationcombinedwithalateralflowbiosensor
AT nacaprichaduangjai rapiddetectionofclostridiumperfringensinfoodbyloopmediatedisothermalamplificationcombinedwithalateralflowbiosensor
AT ounjaipuey rapiddetectionofclostridiumperfringensinfoodbyloopmediatedisothermalamplificationcombinedwithalateralflowbiosensor
AT chankhamhaengdechasurang rapiddetectionofclostridiumperfringensinfoodbyloopmediatedisothermalamplificationcombinedwithalateralflowbiosensor