Cargando…

Model Evaluation of the Influence of the Plunger Stroke on Functional Parameters of the Low-Pressure Pulse Gas Solenoid Injector

The article presents a model-based evaluation of the impact of the plunger stroke on functional parameters of the low-pressure pulse gas solenoid injector. A reduced-order physics-based mathematical model was used to achieve this goal. The model was built on the basis of specified simplifications of...

Descripción completa

Detalles Bibliográficos
Autores principales: Szpica, Dariusz, Kusznier, Michał
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021