Reverse longitudinal stent deformation during percutaneous intervention via the retrograde approach to a chronic total occlusion of the right coronary artery: a case report

BACKGROUND: Longitudinal stent deformation (LSD) is an uncommon but recognized mechanical complication of coronary stent implantation, usually occurring at the proximal stent edge due to compression by guide catheter or catheter extensions. Retrograde techniques for chronic total occlusion (CTO) per...