Cargando…

Computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp

The patch-clamp technique and more recently the high throughput patch-clamp technique have contributed to major advances in the characterization of ion channels. However, the whole-cell voltage-clamp technique presents certain limits that need to be considered for robust data generation. One major c...

Descripción completa

Detalles Bibliográficos
Autores principales: Montnach, Jérôme, Lorenzini, Maxime, Lesage, Adrien, Simon, Isabelle, Nicolas, Sébastien, Moreau, Eléonore, Marionneau, Céline, Baró, Isabelle, De Waard, Michel, Loussouarn, Gildas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7870888/
https://www.ncbi.nlm.nih.gov/pubmed/33558601
http://dx.doi.org/10.1038/s41598-021-82077-8
_version_ 1783648900044816384
author Montnach, Jérôme
Lorenzini, Maxime
Lesage, Adrien
Simon, Isabelle
Nicolas, Sébastien
Moreau, Eléonore
Marionneau, Céline
Baró, Isabelle
De Waard, Michel
Loussouarn, Gildas
author_facet Montnach, Jérôme
Lorenzini, Maxime
Lesage, Adrien
Simon, Isabelle
Nicolas, Sébastien
Moreau, Eléonore
Marionneau, Céline
Baró, Isabelle
De Waard, Michel
Loussouarn, Gildas
author_sort Montnach, Jérôme
collection PubMed
description The patch-clamp technique and more recently the high throughput patch-clamp technique have contributed to major advances in the characterization of ion channels. However, the whole-cell voltage-clamp technique presents certain limits that need to be considered for robust data generation. One major caveat is that increasing current amplitude profoundly impacts the accuracy of the biophysical analyses of macroscopic ion currents under study. Using mathematical kinetic models of a cardiac voltage-gated sodium channel and a cardiac voltage-gated potassium channel, we demonstrated how large current amplitude and series resistance artefacts induce an undetected alteration in the actual membrane potential and affect the characterization of voltage-dependent activation and inactivation processes. We also computed how dose–response curves are hindered by high current amplitudes. This is of high interest since stable cell lines frequently demonstrating high current amplitudes are used for safety pharmacology using the high throughput patch-clamp technique. It is therefore critical to set experimental limits for current amplitude recordings to prevent inaccuracy in the characterization of channel properties or drug activity, such limits being different from one channel type to another. Based on the predictions generated by the kinetic models, we draw simple guidelines for good practice of whole-cell voltage-clamp recordings.
format Online
Article
Text
id pubmed-7870888
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-78708882021-02-10 Computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp Montnach, Jérôme Lorenzini, Maxime Lesage, Adrien Simon, Isabelle Nicolas, Sébastien Moreau, Eléonore Marionneau, Céline Baró, Isabelle De Waard, Michel Loussouarn, Gildas Sci Rep Article The patch-clamp technique and more recently the high throughput patch-clamp technique have contributed to major advances in the characterization of ion channels. However, the whole-cell voltage-clamp technique presents certain limits that need to be considered for robust data generation. One major caveat is that increasing current amplitude profoundly impacts the accuracy of the biophysical analyses of macroscopic ion currents under study. Using mathematical kinetic models of a cardiac voltage-gated sodium channel and a cardiac voltage-gated potassium channel, we demonstrated how large current amplitude and series resistance artefacts induce an undetected alteration in the actual membrane potential and affect the characterization of voltage-dependent activation and inactivation processes. We also computed how dose–response curves are hindered by high current amplitudes. This is of high interest since stable cell lines frequently demonstrating high current amplitudes are used for safety pharmacology using the high throughput patch-clamp technique. It is therefore critical to set experimental limits for current amplitude recordings to prevent inaccuracy in the characterization of channel properties or drug activity, such limits being different from one channel type to another. Based on the predictions generated by the kinetic models, we draw simple guidelines for good practice of whole-cell voltage-clamp recordings. Nature Publishing Group UK 2021-02-08 /pmc/articles/PMC7870888/ /pubmed/33558601 http://dx.doi.org/10.1038/s41598-021-82077-8 Text en © The Author(s) 2021 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Montnach, Jérôme
Lorenzini, Maxime
Lesage, Adrien
Simon, Isabelle
Nicolas, Sébastien
Moreau, Eléonore
Marionneau, Céline
Baró, Isabelle
De Waard, Michel
Loussouarn, Gildas
Computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp
title Computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp
title_full Computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp
title_fullStr Computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp
title_full_unstemmed Computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp
title_short Computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp
title_sort computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7870888/
https://www.ncbi.nlm.nih.gov/pubmed/33558601
http://dx.doi.org/10.1038/s41598-021-82077-8
work_keys_str_mv AT montnachjerome computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp
AT lorenzinimaxime computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp
AT lesageadrien computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp
AT simonisabelle computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp
AT nicolassebastien computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp
AT moreaueleonore computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp
AT marionneauceline computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp
AT baroisabelle computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp
AT dewaardmichel computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp
AT loussouarngildas computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp