Cargando…
Computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp
The patch-clamp technique and more recently the high throughput patch-clamp technique have contributed to major advances in the characterization of ion channels. However, the whole-cell voltage-clamp technique presents certain limits that need to be considered for robust data generation. One major c...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7870888/ https://www.ncbi.nlm.nih.gov/pubmed/33558601 http://dx.doi.org/10.1038/s41598-021-82077-8 |
_version_ | 1783648900044816384 |
---|---|
author | Montnach, Jérôme Lorenzini, Maxime Lesage, Adrien Simon, Isabelle Nicolas, Sébastien Moreau, Eléonore Marionneau, Céline Baró, Isabelle De Waard, Michel Loussouarn, Gildas |
author_facet | Montnach, Jérôme Lorenzini, Maxime Lesage, Adrien Simon, Isabelle Nicolas, Sébastien Moreau, Eléonore Marionneau, Céline Baró, Isabelle De Waard, Michel Loussouarn, Gildas |
author_sort | Montnach, Jérôme |
collection | PubMed |
description | The patch-clamp technique and more recently the high throughput patch-clamp technique have contributed to major advances in the characterization of ion channels. However, the whole-cell voltage-clamp technique presents certain limits that need to be considered for robust data generation. One major caveat is that increasing current amplitude profoundly impacts the accuracy of the biophysical analyses of macroscopic ion currents under study. Using mathematical kinetic models of a cardiac voltage-gated sodium channel and a cardiac voltage-gated potassium channel, we demonstrated how large current amplitude and series resistance artefacts induce an undetected alteration in the actual membrane potential and affect the characterization of voltage-dependent activation and inactivation processes. We also computed how dose–response curves are hindered by high current amplitudes. This is of high interest since stable cell lines frequently demonstrating high current amplitudes are used for safety pharmacology using the high throughput patch-clamp technique. It is therefore critical to set experimental limits for current amplitude recordings to prevent inaccuracy in the characterization of channel properties or drug activity, such limits being different from one channel type to another. Based on the predictions generated by the kinetic models, we draw simple guidelines for good practice of whole-cell voltage-clamp recordings. |
format | Online Article Text |
id | pubmed-7870888 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-78708882021-02-10 Computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp Montnach, Jérôme Lorenzini, Maxime Lesage, Adrien Simon, Isabelle Nicolas, Sébastien Moreau, Eléonore Marionneau, Céline Baró, Isabelle De Waard, Michel Loussouarn, Gildas Sci Rep Article The patch-clamp technique and more recently the high throughput patch-clamp technique have contributed to major advances in the characterization of ion channels. However, the whole-cell voltage-clamp technique presents certain limits that need to be considered for robust data generation. One major caveat is that increasing current amplitude profoundly impacts the accuracy of the biophysical analyses of macroscopic ion currents under study. Using mathematical kinetic models of a cardiac voltage-gated sodium channel and a cardiac voltage-gated potassium channel, we demonstrated how large current amplitude and series resistance artefacts induce an undetected alteration in the actual membrane potential and affect the characterization of voltage-dependent activation and inactivation processes. We also computed how dose–response curves are hindered by high current amplitudes. This is of high interest since stable cell lines frequently demonstrating high current amplitudes are used for safety pharmacology using the high throughput patch-clamp technique. It is therefore critical to set experimental limits for current amplitude recordings to prevent inaccuracy in the characterization of channel properties or drug activity, such limits being different from one channel type to another. Based on the predictions generated by the kinetic models, we draw simple guidelines for good practice of whole-cell voltage-clamp recordings. Nature Publishing Group UK 2021-02-08 /pmc/articles/PMC7870888/ /pubmed/33558601 http://dx.doi.org/10.1038/s41598-021-82077-8 Text en © The Author(s) 2021 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Montnach, Jérôme Lorenzini, Maxime Lesage, Adrien Simon, Isabelle Nicolas, Sébastien Moreau, Eléonore Marionneau, Céline Baró, Isabelle De Waard, Michel Loussouarn, Gildas Computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp |
title | Computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp |
title_full | Computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp |
title_fullStr | Computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp |
title_full_unstemmed | Computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp |
title_short | Computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp |
title_sort | computer modeling of whole-cell voltage-clamp analyses to delineate guidelines for good practice of manual and automated patch-clamp |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7870888/ https://www.ncbi.nlm.nih.gov/pubmed/33558601 http://dx.doi.org/10.1038/s41598-021-82077-8 |
work_keys_str_mv | AT montnachjerome computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp AT lorenzinimaxime computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp AT lesageadrien computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp AT simonisabelle computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp AT nicolassebastien computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp AT moreaueleonore computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp AT marionneauceline computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp AT baroisabelle computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp AT dewaardmichel computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp AT loussouarngildas computermodelingofwholecellvoltageclampanalysestodelineateguidelinesforgoodpracticeofmanualandautomatedpatchclamp |