Biomechanical evaluation of self-cinching stitch techniques in rotator cuff repair: The single-loop and double-loop knot stitches
In rotator cuff repair, strong and reliable suturing is necessary to decrease failure rates. The biomechanics of two self-cinching stitches – the single-loop knot stitch (SLKS) and the double-loop knot stitch (DLKS) – and the modified Mason-Allen stitch (mMAS) were compared. Twenty-seven porcine inf...