Cargando…

Corrosion resistance assessment of nickel-titanium endodontic files with and without heat treatment

OBJECTIVES: The aim of this study was to evaluate the corrosion resistance of heat-treated (Reciproc and WaveOne) and non-heat-treated (ProTaper and Mtwo) superelastic nickel-titanium endodontic files when immersed in a 5.25% sodium hypochlorite solution. MATERIALS AND METHODS: Anodic polarization c...

Descripción completa

Detalles Bibliográficos
Autores principales: Costa, Tatiana Dias, Silva, Elison da Fonseca e, Caetano, Paula Liparini, Campos, Marcio José da Silva, Resende, Leandro Marques, Machado, André Guimarães, do Carmo, Antônio Márcio Resende
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Conservative Dentistry 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7906845/
https://www.ncbi.nlm.nih.gov/pubmed/33680895
http://dx.doi.org/10.5395/rde.2021.46.e6