Cargando…
A Modified Limiting Dilution Method for Monoclonal Stable Cell Line Selection Using a Real-Time Fluorescence Imaging System: A Practical Workflow and Advanced Applications
Stable cell lines are widely used in laboratory research and pharmaceutical industry. They are mainly applied in recombinant protein and antibody productions, gene function studies, drug screens, toxicity assessments, and for cancer therapy investigation. There are two types of cell lines, polyclona...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7931037/ https://www.ncbi.nlm.nih.gov/pubmed/33672596 http://dx.doi.org/10.3390/mps4010016 |
_version_ | 1783660210643009536 |
---|---|
author | Ye, Mingyu Wilhelm, Martina Gentschev, Ivaylo Szalay, Aladár |
author_facet | Ye, Mingyu Wilhelm, Martina Gentschev, Ivaylo Szalay, Aladár |
author_sort | Ye, Mingyu |
collection | PubMed |
description | Stable cell lines are widely used in laboratory research and pharmaceutical industry. They are mainly applied in recombinant protein and antibody productions, gene function studies, drug screens, toxicity assessments, and for cancer therapy investigation. There are two types of cell lines, polyclonal and monoclonal origin, that differ regarding their homogeneity and heterogeneity. Generating a high-quality stable cell line, which can grow continuously and carry a stable genetic modification without alteration is very important for most studies, because polyclonal cell lines of multicellular origin can be highly variable and unstable and lead to inconclusive experimental results. The most commonly used technologies of single cell originate monoclonal stable cell isolation in laboratory are fluorescence-activated cell sorting (FACS) sorting and limiting dilution cloning. Here, we describe a modified limiting dilution method of monoclonal stable cell line selection using the real-time fluorescence imaging system IncuCyte(®)S3. |
format | Online Article Text |
id | pubmed-7931037 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-79310372021-03-05 A Modified Limiting Dilution Method for Monoclonal Stable Cell Line Selection Using a Real-Time Fluorescence Imaging System: A Practical Workflow and Advanced Applications Ye, Mingyu Wilhelm, Martina Gentschev, Ivaylo Szalay, Aladár Methods Protoc Study Protocol Stable cell lines are widely used in laboratory research and pharmaceutical industry. They are mainly applied in recombinant protein and antibody productions, gene function studies, drug screens, toxicity assessments, and for cancer therapy investigation. There are two types of cell lines, polyclonal and monoclonal origin, that differ regarding their homogeneity and heterogeneity. Generating a high-quality stable cell line, which can grow continuously and carry a stable genetic modification without alteration is very important for most studies, because polyclonal cell lines of multicellular origin can be highly variable and unstable and lead to inconclusive experimental results. The most commonly used technologies of single cell originate monoclonal stable cell isolation in laboratory are fluorescence-activated cell sorting (FACS) sorting and limiting dilution cloning. Here, we describe a modified limiting dilution method of monoclonal stable cell line selection using the real-time fluorescence imaging system IncuCyte(®)S3. MDPI 2021-02-20 /pmc/articles/PMC7931037/ /pubmed/33672596 http://dx.doi.org/10.3390/mps4010016 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Study Protocol Ye, Mingyu Wilhelm, Martina Gentschev, Ivaylo Szalay, Aladár A Modified Limiting Dilution Method for Monoclonal Stable Cell Line Selection Using a Real-Time Fluorescence Imaging System: A Practical Workflow and Advanced Applications |
title | A Modified Limiting Dilution Method for Monoclonal Stable Cell Line Selection Using a Real-Time Fluorescence Imaging System: A Practical Workflow and Advanced Applications |
title_full | A Modified Limiting Dilution Method for Monoclonal Stable Cell Line Selection Using a Real-Time Fluorescence Imaging System: A Practical Workflow and Advanced Applications |
title_fullStr | A Modified Limiting Dilution Method for Monoclonal Stable Cell Line Selection Using a Real-Time Fluorescence Imaging System: A Practical Workflow and Advanced Applications |
title_full_unstemmed | A Modified Limiting Dilution Method for Monoclonal Stable Cell Line Selection Using a Real-Time Fluorescence Imaging System: A Practical Workflow and Advanced Applications |
title_short | A Modified Limiting Dilution Method for Monoclonal Stable Cell Line Selection Using a Real-Time Fluorescence Imaging System: A Practical Workflow and Advanced Applications |
title_sort | modified limiting dilution method for monoclonal stable cell line selection using a real-time fluorescence imaging system: a practical workflow and advanced applications |
topic | Study Protocol |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7931037/ https://www.ncbi.nlm.nih.gov/pubmed/33672596 http://dx.doi.org/10.3390/mps4010016 |
work_keys_str_mv | AT yemingyu amodifiedlimitingdilutionmethodformonoclonalstablecelllineselectionusingarealtimefluorescenceimagingsystemapracticalworkflowandadvancedapplications AT wilhelmmartina amodifiedlimitingdilutionmethodformonoclonalstablecelllineselectionusingarealtimefluorescenceimagingsystemapracticalworkflowandadvancedapplications AT gentschevivaylo amodifiedlimitingdilutionmethodformonoclonalstablecelllineselectionusingarealtimefluorescenceimagingsystemapracticalworkflowandadvancedapplications AT szalayaladar amodifiedlimitingdilutionmethodformonoclonalstablecelllineselectionusingarealtimefluorescenceimagingsystemapracticalworkflowandadvancedapplications AT yemingyu modifiedlimitingdilutionmethodformonoclonalstablecelllineselectionusingarealtimefluorescenceimagingsystemapracticalworkflowandadvancedapplications AT wilhelmmartina modifiedlimitingdilutionmethodformonoclonalstablecelllineselectionusingarealtimefluorescenceimagingsystemapracticalworkflowandadvancedapplications AT gentschevivaylo modifiedlimitingdilutionmethodformonoclonalstablecelllineselectionusingarealtimefluorescenceimagingsystemapracticalworkflowandadvancedapplications AT szalayaladar modifiedlimitingdilutionmethodformonoclonalstablecelllineselectionusingarealtimefluorescenceimagingsystemapracticalworkflowandadvancedapplications |