Compartmental Differences in Macular Retinal Ganglion Cell Function
PURPOSE: The purpose of this study was to investigate local differences of macular retinal ganglion cell (RGC) function by means of the steady-state pattern electroretinogram (SS-PERG). METHODS: SS-PERGs were recorded in healthy subjects (n = 43) in response to gratings (1.6 c/deg, 15.63 reversals/s...