A Compensation Method for Nonlinear Vibration of Silicon-Micro Resonant Sensor

A compensation method for nonlinear vibration of a silicon micro resonant sensor is proposed and evaluated to be effective through simulation and experimental analysis. Firstly, the parameter characterization model of the silicon micro resonant sensor is established, which presents significant nonli...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Yan, Li, Hao, Xiao, Yifeng, Cao, Le, Guo, Zhan-She
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8038624/
https://www.ncbi.nlm.nih.gov/pubmed/33916484
http://dx.doi.org/10.3390/s21072545
_version_ 1783677418544824320
author Li, Yan
Li, Hao
Xiao, Yifeng
Cao, Le
Guo, Zhan-She
author_facet Li, Yan
Li, Hao
Xiao, Yifeng
Cao, Le
Guo, Zhan-She
author_sort Li, Yan
collection PubMed
description A compensation method for nonlinear vibration of a silicon micro resonant sensor is proposed and evaluated to be effective through simulation and experimental analysis. Firstly, the parameter characterization model of the silicon micro resonant sensor is established, which presents significant nonlinearity because of the nonlinear vibration of the resonant beam. A verification circuit is devised to imitate the nonlinear behavior of the model by matching the simulation measurement error of the frequency offset produced by the circuit block with the theoretical counterparts obtained from the model. Secondly, the principle of measurement error compensation is studied, and the compensation method dealing with nonlinear characteristics of the resonant beam is proposed by introducing a compensation beam and corresponding differential operations. The measurement error, compensation rate, and measurement residual between the two scenarios that use single beam and double beams, respectively, are derived and are compared with their simulation and experimental counterparts. The results coincide with the predicted trend, which verifies the effectiveness of the compensation method.
format Online
Article
Text
id pubmed-8038624
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-80386242021-04-12 A Compensation Method for Nonlinear Vibration of Silicon-Micro Resonant Sensor Li, Yan Li, Hao Xiao, Yifeng Cao, Le Guo, Zhan-She Sensors (Basel) Article A compensation method for nonlinear vibration of a silicon micro resonant sensor is proposed and evaluated to be effective through simulation and experimental analysis. Firstly, the parameter characterization model of the silicon micro resonant sensor is established, which presents significant nonlinearity because of the nonlinear vibration of the resonant beam. A verification circuit is devised to imitate the nonlinear behavior of the model by matching the simulation measurement error of the frequency offset produced by the circuit block with the theoretical counterparts obtained from the model. Secondly, the principle of measurement error compensation is studied, and the compensation method dealing with nonlinear characteristics of the resonant beam is proposed by introducing a compensation beam and corresponding differential operations. The measurement error, compensation rate, and measurement residual between the two scenarios that use single beam and double beams, respectively, are derived and are compared with their simulation and experimental counterparts. The results coincide with the predicted trend, which verifies the effectiveness of the compensation method. MDPI 2021-04-05 /pmc/articles/PMC8038624/ /pubmed/33916484 http://dx.doi.org/10.3390/s21072545 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Li, Yan
Li, Hao
Xiao, Yifeng
Cao, Le
Guo, Zhan-She
A Compensation Method for Nonlinear Vibration of Silicon-Micro Resonant Sensor
title A Compensation Method for Nonlinear Vibration of Silicon-Micro Resonant Sensor
title_full A Compensation Method for Nonlinear Vibration of Silicon-Micro Resonant Sensor
title_fullStr A Compensation Method for Nonlinear Vibration of Silicon-Micro Resonant Sensor
title_full_unstemmed A Compensation Method for Nonlinear Vibration of Silicon-Micro Resonant Sensor
title_short A Compensation Method for Nonlinear Vibration of Silicon-Micro Resonant Sensor
title_sort compensation method for nonlinear vibration of silicon-micro resonant sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8038624/
https://www.ncbi.nlm.nih.gov/pubmed/33916484
http://dx.doi.org/10.3390/s21072545
work_keys_str_mv AT liyan acompensationmethodfornonlinearvibrationofsiliconmicroresonantsensor
AT lihao acompensationmethodfornonlinearvibrationofsiliconmicroresonantsensor
AT xiaoyifeng acompensationmethodfornonlinearvibrationofsiliconmicroresonantsensor
AT caole acompensationmethodfornonlinearvibrationofsiliconmicroresonantsensor
AT guozhanshe acompensationmethodfornonlinearvibrationofsiliconmicroresonantsensor
AT liyan compensationmethodfornonlinearvibrationofsiliconmicroresonantsensor
AT lihao compensationmethodfornonlinearvibrationofsiliconmicroresonantsensor
AT xiaoyifeng compensationmethodfornonlinearvibrationofsiliconmicroresonantsensor
AT caole compensationmethodfornonlinearvibrationofsiliconmicroresonantsensor
AT guozhanshe compensationmethodfornonlinearvibrationofsiliconmicroresonantsensor