MEDICOLEGAL CORNER. Failure to replace obstructed lumbar drain after thoracic-abdominal aortic aneurysm repair leads to paraplegia
BACKGROUND: To avoid spinal cord ischemia following endovascular/open thoracic-abdominal aortic aneurysm (T-AAA) repair, lumbar drains (LDs) are placed to reduce intraspinal pressure, and increase spinal perfusion pressure. Here, we present a medicolegal case in which a critical care (CC) physician...