Sudden unexpected improvement in the atrioventricular conduction. What is the mechanism?

The 12-lead electrocardiogram (ECG) of a 79-year-old male patient with recurrent pre-syncope showed irregular sinus rhythm with constant PR interval and left bundle branch block (LBBB) with intermittently blocked P waves. The beat following the blocked P wave had a narrower QRS with a shorter PR int...

Descripción completa

Detalles Bibliográficos
Autores principales: Gupta, Anunay, Bhargava, Kartikeya, Bhasin, Dinkar, Agstam, Sourabh, Isser, Hermohander Singh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021