Cargando…

Pharmacokinetic comparison with different assays for simultaneous determination of cis-, trans-cefprozil diastereomers in human plasma

The purpose of this study was to compare pharmacokinetic (PK) parameters obtained using two newly developed assays, HPLC-UV and UPLC-ESI-MS/MS. Selection of assay and results obtained therefrom are very important in PK studies and can have a major impact on the PK-based clinical dose and usage setti...

Descripción completa

Detalles Bibliográficos
Autores principales: Jeong, Seung-Hyun, Jang, Ji-Hun, Cho, Hea-Young, Lee, Yong-Bok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Xi'an Jiaotong University 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8264462/
https://www.ncbi.nlm.nih.gov/pubmed/34277123
http://dx.doi.org/10.1016/j.jpha.2020.07.001
_version_ 1783719562259202048
author Jeong, Seung-Hyun
Jang, Ji-Hun
Cho, Hea-Young
Lee, Yong-Bok
author_facet Jeong, Seung-Hyun
Jang, Ji-Hun
Cho, Hea-Young
Lee, Yong-Bok
author_sort Jeong, Seung-Hyun
collection PubMed
description The purpose of this study was to compare pharmacokinetic (PK) parameters obtained using two newly developed assays, HPLC-UV and UPLC-ESI-MS/MS. Selection of assay and results obtained therefrom are very important in PK studies and can have a major impact on the PK-based clinical dose and usage settings. For this study, we developed two new methods that are most commonly used in biosample analysis and focused on PK parameters obtained from them. By HPLC-UV equipped with a Luna-C(8) column using UV detector, cefprozil diastereomers were separated using water containing 2% (V/V) acetic acid and acetonitrile as a mobile phase. By UPLC-ESI-MS/MS equipped with a HALO-C(18)column, cefprozil diastereomers were separated using 0.5% (V/V) aqueous formic acid containing 5 mM ammonium-formate buffer and methanol as a mobile phase. Chromatograms showed high resolution, sensitivity, and selectivity without interference by plasma constituents. Both intra- and inter-day precisions (CV, %) were within 8.88% for HPLC-UV and UPLC-ESI-MS/MS. Accuracy of both methods was 95.67%–107.50%. These two analytical methods satisfied the criteria of international guidance and could be successfully applied to PK study. Comparison of PK parameters between two assays confirmed that there is a difference in the predicted minimum plasma concentrations at steady state, which may affect clinical dose and usage settings. Furthermore, we confirmed possible correlation between PK parameters and various biochemical parameters after oral administration of 1000 mg cefprozil to humans.
format Online
Article
Text
id pubmed-8264462
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Xi'an Jiaotong University
record_format MEDLINE/PubMed
spelling pubmed-82644622021-07-16 Pharmacokinetic comparison with different assays for simultaneous determination of cis-, trans-cefprozil diastereomers in human plasma Jeong, Seung-Hyun Jang, Ji-Hun Cho, Hea-Young Lee, Yong-Bok J Pharm Anal Original Article The purpose of this study was to compare pharmacokinetic (PK) parameters obtained using two newly developed assays, HPLC-UV and UPLC-ESI-MS/MS. Selection of assay and results obtained therefrom are very important in PK studies and can have a major impact on the PK-based clinical dose and usage settings. For this study, we developed two new methods that are most commonly used in biosample analysis and focused on PK parameters obtained from them. By HPLC-UV equipped with a Luna-C(8) column using UV detector, cefprozil diastereomers were separated using water containing 2% (V/V) acetic acid and acetonitrile as a mobile phase. By UPLC-ESI-MS/MS equipped with a HALO-C(18)column, cefprozil diastereomers were separated using 0.5% (V/V) aqueous formic acid containing 5 mM ammonium-formate buffer and methanol as a mobile phase. Chromatograms showed high resolution, sensitivity, and selectivity without interference by plasma constituents. Both intra- and inter-day precisions (CV, %) were within 8.88% for HPLC-UV and UPLC-ESI-MS/MS. Accuracy of both methods was 95.67%–107.50%. These two analytical methods satisfied the criteria of international guidance and could be successfully applied to PK study. Comparison of PK parameters between two assays confirmed that there is a difference in the predicted minimum plasma concentrations at steady state, which may affect clinical dose and usage settings. Furthermore, we confirmed possible correlation between PK parameters and various biochemical parameters after oral administration of 1000 mg cefprozil to humans. Xi'an Jiaotong University 2021-06 2020-07-05 /pmc/articles/PMC8264462/ /pubmed/34277123 http://dx.doi.org/10.1016/j.jpha.2020.07.001 Text en © 2020 Xi'an Jiaotong University. Production and hosting by Elsevier B.V. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Jeong, Seung-Hyun
Jang, Ji-Hun
Cho, Hea-Young
Lee, Yong-Bok
Pharmacokinetic comparison with different assays for simultaneous determination of cis-, trans-cefprozil diastereomers in human plasma
title Pharmacokinetic comparison with different assays for simultaneous determination of cis-, trans-cefprozil diastereomers in human plasma
title_full Pharmacokinetic comparison with different assays for simultaneous determination of cis-, trans-cefprozil diastereomers in human plasma
title_fullStr Pharmacokinetic comparison with different assays for simultaneous determination of cis-, trans-cefprozil diastereomers in human plasma
title_full_unstemmed Pharmacokinetic comparison with different assays for simultaneous determination of cis-, trans-cefprozil diastereomers in human plasma
title_short Pharmacokinetic comparison with different assays for simultaneous determination of cis-, trans-cefprozil diastereomers in human plasma
title_sort pharmacokinetic comparison with different assays for simultaneous determination of cis-, trans-cefprozil diastereomers in human plasma
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8264462/
https://www.ncbi.nlm.nih.gov/pubmed/34277123
http://dx.doi.org/10.1016/j.jpha.2020.07.001
work_keys_str_mv AT jeongseunghyun pharmacokineticcomparisonwithdifferentassaysforsimultaneousdeterminationofcistranscefprozildiastereomersinhumanplasma
AT jangjihun pharmacokineticcomparisonwithdifferentassaysforsimultaneousdeterminationofcistranscefprozildiastereomersinhumanplasma
AT choheayoung pharmacokineticcomparisonwithdifferentassaysforsimultaneousdeterminationofcistranscefprozildiastereomersinhumanplasma
AT leeyongbok pharmacokineticcomparisonwithdifferentassaysforsimultaneousdeterminationofcistranscefprozildiastereomersinhumanplasma