Carbon Ion Dose Constraints in the Head and Neck and Skull Base: Review of MedAustron Institutional Protocols

BACKGROUND: Dose constraints are of paramount importance for the outcome of any radiotherapy treatment. In this article, we report dose-volume constraints as well as currently used fractionation schedules for carbon ion radiotherapy as applied in MedAustron (Wiener Neustadt, Austria). MATERIALS AND...

Descripción completa

Detalles Bibliográficos
Autores principales: Fossati, Piero, Perpar, Ana, Stock, Markus, Georg, Petra, Carlino, Antonio, Gora, Joanna, Martino, Giovanna, Hug, Eugen B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Particle Therapy Co-operative Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8270085/
https://www.ncbi.nlm.nih.gov/pubmed/34285933