Multivariate data analysis of capacitance frequency scanning for online monitoring of viable cell concentrations in small-scale bioreactors
Viable cell concentration (VCC) is one of the most important process attributes during mammalian cell cultivations. Current state-of-the-art measurements of VCC comprise offline methods which do not allow for continuous process data. According to the FDA’s process analytical technology initiative, p...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8285309/ https://www.ncbi.nlm.nih.gov/pubmed/31608427 http://dx.doi.org/10.1007/s00216-019-02096-3 |
_version_ | 1783723535041036288 |
---|---|
author | Metze, Sabrina Blioch, Stefanie Matuszczyk, Jens Greller, Gerhard Grimm, Christian Scholz, Jochen Hoehse, Marek |
author_facet | Metze, Sabrina Blioch, Stefanie Matuszczyk, Jens Greller, Gerhard Grimm, Christian Scholz, Jochen Hoehse, Marek |
author_sort | Metze, Sabrina |
collection | PubMed |
description | Viable cell concentration (VCC) is one of the most important process attributes during mammalian cell cultivations. Current state-of-the-art measurements of VCC comprise offline methods which do not allow for continuous process data. According to the FDA’s process analytical technology initiative, process monitoring and control should be applied to gain process understanding and to ensure high product quality. In this work, the use of an inline capacitance probe to monitor online VCCs of a mammalian CHO cell culture process in small-scale bioreactors (250 mL) was investigated. Capacitance sensors using single frequency are increasingly common for biomass monitoring. However, the single-frequency signal corresponds to the cell polarization that represents the viable cell volume. Therefore single-frequency measurements are dependent on cell diameter changes. Measuring the capacitance across various frequencies (frequency scanning) can provide information about the VCC and cope with changing cell diameter. Applying multivariate data analysis on the frequency scanning data successfully enabled direct online monitoring of VCCs in this study. The multivariate model was trained with data from 5 standard cultivations. The model provided a prediction of VCCs with relative errors from 5.5 to 11%, which is a good agreement with the acceptance criterion based on the offline reference method accuracy (approximately 10% relative error) and strongly improved compared with single-frequency results (16 to 23% relative error). Furthermore, robustness trials were conducted to demonstrate the model’s predictive ability under challenging conditions. The process deviations in regard to dilution steps and feed variations were detected immediately in the online prediction of the VCC with relative errors between 6.7 and 13.2%. Thus in summary, the presented method on capacitance frequency scanning demonstrates its suitability for process monitoring and control that can save batches, time, and cost. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00216-019-02096-3) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-8285309 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-82853092021-07-20 Multivariate data analysis of capacitance frequency scanning for online monitoring of viable cell concentrations in small-scale bioreactors Metze, Sabrina Blioch, Stefanie Matuszczyk, Jens Greller, Gerhard Grimm, Christian Scholz, Jochen Hoehse, Marek Anal Bioanal Chem Research Paper Viable cell concentration (VCC) is one of the most important process attributes during mammalian cell cultivations. Current state-of-the-art measurements of VCC comprise offline methods which do not allow for continuous process data. According to the FDA’s process analytical technology initiative, process monitoring and control should be applied to gain process understanding and to ensure high product quality. In this work, the use of an inline capacitance probe to monitor online VCCs of a mammalian CHO cell culture process in small-scale bioreactors (250 mL) was investigated. Capacitance sensors using single frequency are increasingly common for biomass monitoring. However, the single-frequency signal corresponds to the cell polarization that represents the viable cell volume. Therefore single-frequency measurements are dependent on cell diameter changes. Measuring the capacitance across various frequencies (frequency scanning) can provide information about the VCC and cope with changing cell diameter. Applying multivariate data analysis on the frequency scanning data successfully enabled direct online monitoring of VCCs in this study. The multivariate model was trained with data from 5 standard cultivations. The model provided a prediction of VCCs with relative errors from 5.5 to 11%, which is a good agreement with the acceptance criterion based on the offline reference method accuracy (approximately 10% relative error) and strongly improved compared with single-frequency results (16 to 23% relative error). Furthermore, robustness trials were conducted to demonstrate the model’s predictive ability under challenging conditions. The process deviations in regard to dilution steps and feed variations were detected immediately in the online prediction of the VCC with relative errors between 6.7 and 13.2%. Thus in summary, the presented method on capacitance frequency scanning demonstrates its suitability for process monitoring and control that can save batches, time, and cost. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00216-019-02096-3) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2019-10-13 2020 /pmc/articles/PMC8285309/ /pubmed/31608427 http://dx.doi.org/10.1007/s00216-019-02096-3 Text en © The Author(s) 2019 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Paper Metze, Sabrina Blioch, Stefanie Matuszczyk, Jens Greller, Gerhard Grimm, Christian Scholz, Jochen Hoehse, Marek Multivariate data analysis of capacitance frequency scanning for online monitoring of viable cell concentrations in small-scale bioreactors |
title | Multivariate data analysis of capacitance frequency scanning for online monitoring of viable cell concentrations in small-scale bioreactors |
title_full | Multivariate data analysis of capacitance frequency scanning for online monitoring of viable cell concentrations in small-scale bioreactors |
title_fullStr | Multivariate data analysis of capacitance frequency scanning for online monitoring of viable cell concentrations in small-scale bioreactors |
title_full_unstemmed | Multivariate data analysis of capacitance frequency scanning for online monitoring of viable cell concentrations in small-scale bioreactors |
title_short | Multivariate data analysis of capacitance frequency scanning for online monitoring of viable cell concentrations in small-scale bioreactors |
title_sort | multivariate data analysis of capacitance frequency scanning for online monitoring of viable cell concentrations in small-scale bioreactors |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8285309/ https://www.ncbi.nlm.nih.gov/pubmed/31608427 http://dx.doi.org/10.1007/s00216-019-02096-3 |
work_keys_str_mv | AT metzesabrina multivariatedataanalysisofcapacitancefrequencyscanningforonlinemonitoringofviablecellconcentrationsinsmallscalebioreactors AT bliochstefanie multivariatedataanalysisofcapacitancefrequencyscanningforonlinemonitoringofviablecellconcentrationsinsmallscalebioreactors AT matuszczykjens multivariatedataanalysisofcapacitancefrequencyscanningforonlinemonitoringofviablecellconcentrationsinsmallscalebioreactors AT grellergerhard multivariatedataanalysisofcapacitancefrequencyscanningforonlinemonitoringofviablecellconcentrationsinsmallscalebioreactors AT grimmchristian multivariatedataanalysisofcapacitancefrequencyscanningforonlinemonitoringofviablecellconcentrationsinsmallscalebioreactors AT scholzjochen multivariatedataanalysisofcapacitancefrequencyscanningforonlinemonitoringofviablecellconcentrationsinsmallscalebioreactors AT hoehsemarek multivariatedataanalysisofcapacitancefrequencyscanningforonlinemonitoringofviablecellconcentrationsinsmallscalebioreactors |